----------------------------------------------------------------------------------------------------------------- UVP5 Pilot Module, version 7.26 2018/01/21 Pilot Starting Time : 20180317_1709 Project path : C:\\uvp5_sn201_2018_naames_04 ----------------------------------------------------------------------------------------------------------------- => Checking COMPUTER Communication ports Port list = COM3;COM4; > COM PORT 4 being checked now for UVP5 status messages > COM4 OPEN SURV : 03/17 17:13:55 359° 25°C 28.5V -0.1m > Message V092... UVP running now => Testing if UVP5 responds to SBTY messages > UVP RUN_OK or V092 messages received ----------------------------------------------------------------------------------------------------------------- ACTION : TURN ON UVP5 light (test / alignment) ----------------------------------------------------------------------------------------------------------------- > COM4 OPEN NOW => TRYING TO STANDBY UVP5 sent: U013STBY_PRG! UVP STBY_OK messages received > Responding time = 1 sec. => POWERING LIGHTS sent: U024SET_OUTPUT_00000001! UVP5 LIGHT POWERED => START LIGHTS for 30s sent: U024SET_OUTPUT_00000101! UVP5 LIGHT ON for 30s => STOP LIGHT and POWER OFF sent: U024SET_OUTPUT_00000000! UVP5 LIGHT FLASHING for 30s UVP RUN_OK messages received > COM4 CLOSED NOW ----------------------------------------------------------------------------------------------------------------- ACTION : TURN ON UVP5 light (test / alignment) ----------------------------------------------------------------------------------------------------------------- > COM4 OPEN NOW => TRYING TO STANDBY UVP5 sent: U013STBY_PRG! UVP STBY_OK messages received > Responding time = 1.05 sec. => POWERING LIGHTS sent: U024SET_OUTPUT_00000001! UVP5 LIGHT POWERED => START LIGHTS for 30s sent: U024SET_OUTPUT_00000101! UVP5 LIGHT ON for 30s => STOP LIGHT and POWER OFF sent: U024SET_OUTPUT_00000000! UVP5 LIGHT FLASHING for 30s UVP RUN_OK messages received > COM4 CLOSED NOW ----------------------------------------------------------------------------------------------------------------- ACTION : TURN ON UVP5 light (test / alignment) ----------------------------------------------------------------------------------------------------------------- > COM4 OPEN NOW => TRYING TO STANDBY UVP5 sent: U013STBY_PRG! UVP STBY_OK messages received > Responding time = 1 sec. => POWERING LIGHTS sent: U024SET_OUTPUT_00000001! UVP5 LIGHT POWERED => START LIGHTS for 30s sent: U024SET_OUTPUT_00000101! UVP5 LIGHT ON for 30s => STOP LIGHT and POWER OFF sent: U024SET_OUTPUT_00000000! UVP5 LIGHT FLASHING for 30s UVP RUN_OK messages received > COM4 CLOSED NOW ----------------------------------------------------------------------------------------------------------------- ACTION : EXIT PILOT MODULE ----------------------------------------------------------------------------------------------------------------- > COM4 CLOSED ----------------------------------------------------------------------------------------------------------------- PILOT MODULE CLOSED -----------------------------------------------------------------------------------------------------------------