Brochure/specifications
Manual
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes |
11plus V2 | DECK UNIT for 911plus CTD - Version 2 (V2) includes IEEE-488 & RS-232 interfaces, water sampler modem channel, NMEA 0183 GPS interface, A/D input channel for Surface PAR reference sensor, ASCII serial data output port, CTD pressure signal output, audible bottom contact alarm, audio tape interface, 115/230 VAC (switchable) input power, AC power cord, 10 m CTD test cable, NMEA test cable, remote output cable, serial data cable, rack mount kit, SEASOFT software, & complete documentation. | For photos of standard shipment,
click here. 9plus provides real-time data when controlled with 11plus V2 Deck Unit. 11plus V2 provides power, decodes data stream, passes data to computer, & allows user control of water sampler. Notes: - Computer, slip ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird. - When used without water sampler, 9plus is deployed in vertical orientation. - Standard & optional auxiliary sensors on 9plus not shown. - Version of 11plus in current production is referred to as 11plus V2. - Seasave version 7.18 or later also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit). |
SBE 11plus V2 Spares & Accessories | ||
11plus V2 Back Panel -- many of remaining parts relate to connections to back panel |
||
31043 | Hardigg Case, AL-2221-0604, White, air tight, breather valve, SS hardware | Hardigg shipping case holds SBE 11plus. |
17556 | Deck Unit signal input cable (from slip rings to Deck Unit), 10m (DN 31371) | Pigtail connects Sea Cable on 11plus V2 to slip rings. |
17557 | Deck Unit signal input cable (from slip rings to Deck Unit), 20m (DN 31371) | |
17841 | Deck Unit signal input cable (from slip rings to Deck Unit), 30m (DN 31371) | |
17912 | Deck Unit signal input cable (from slip rings to Deck Unit), 50m (DN 31371) | |
50086 | 2-pin connector, deck unit seacable input | Connects to Sea Cable on 11plus V2. Included with standard shipment; this is spare. |
80915 | Test cable, 11/33/36 deck unit to 9/32/PDIM, 10 m (DN 31314) | Connects Sea Cable on 11plus V2 to 9plus CTD for testing. Included with standard shipment; this is spare. |
801422 | NMEA Test Cable, DB-9S to MS3106A, SBE 11p/33/36/45, 1.8 m (DN 32786) | Connects NMEA
Input on 11plus V2 to computer
simulating NMEA input for testing 11plus V2 NMEA interface. Included with standard
shipment; this is spare. NMEA simulation program, NMEATest, is part of SEASOFT software, & is installed when you install SBE Data Processing. |
801429 | Remote Data Output Test Cable, DB-9S to MS3106A, 1.8 m (DN 32799) | Connects Remote Out on 11plus V2 to computer to set up Remote Output interface. Cable is included with standard shipment; this is spare. |
171887 | RS-232 serial cable, DB-9F to DB-9M, 3 m (171887) | Connects SBE 11 Interface (RS-232) or Modem Channel on 11plus V2 to computer COM ports. Two cables included with standard shipment; this is spare. |
801367 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704) | Connects Surface PAR Input on 11plus V2 to Surface PAR sensor. |
801368 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704) | |
171890 | RS-232 serial data uplink cable, DB-9P to DB-9S, 3 m |
Null
modem cable connects computer to
Serial Data
Uplink on 11plus V2 back panel. See
171890 for pinouts. 300 baud modem for water sampler control (see note below) & either 9p-11a or 9p-11b is required to support serial data uplink. Serial data is multiplexed into 9plus telemetry stream & de-multiplexed by 11plus V2, outputting to computer through standard 9600 Baud Uplink connector. System supports use of serial data output instrument & water sampler in same cast. If 9p-11b (19200 baud) selected, continuous transmission rate may not exceed 9600 baud (960 bytes/second). Therefore, serial data output instrument must transmit at 19200 baud in burst mode (transmissions separated by intervals with no data transmission, resulting in average rate of 960 bytes/second). *Note: 300 baud modem in 9plus & 11plus has been standard since early 2005. For older instruments, it was optional. |
17015 | AC power cord (US Standard), 2 m | One of these (as applicable) as included with standard shipment; this is spare. |
17824 | AC power cord, European plug, 2 m | |
30017 | SBE 11plus rack mounting kit (spare) | For mounting 11plus V2 in standard rack. Included with standard shipment; this is spare. See document 67059. |
80673 | 11plus modem board | |
40934C | Receiver Board | |
40937C | Digital Board | |
20033 | Mallory SC628MN alarm buzzer | Alarm sounds based on data from bottom contact switch &/or altimeter connected to 9plus, &/or minimum/maximum user-input pressure values. |
22002 | Primary power supply (Power One HTAA-16W-A) | |
80811 | NMEA interface board (V1 deck units only) | |
80040 | LED display board | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
20018 | Cooling Fan | |
80586 | 11plus sea cable power supply | |
19006 | Thumbwheel switch | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
Last modified: 11 Apr 2011
Sea-Bird Home Phone: (+1) 425-643-9866 Fax: (+1) 425-643-9954 E-mail: seabird@seabird.com