Sea-Bird Electronics            Products            Support            Software            Sales            Service            Search/Sitemap

SBE 11plus V2 Deck Unit for 911plus
Configuration Details

div.gif (3429 bytes)

Brochure/specifications     Manual

Note: We do not publish prices on the website. Please contact us [seabird@seabird.com or (+1) 425-643-9866] for pricing.

Part # Description Notes
11plus V2 DECK UNIT for 911plus CTD - Version 2 (V2) includes IEEE-488 & RS-232 interfaces, water sampler modem channel, NMEA 0183 GPS interface, A/D input channel for Surface PAR reference sensor, ASCII serial data output port, CTD pressure signal output, audible bottom contact alarm, audio tape interface, 115/230 VAC (switchable) input power, AC power cord, 10 m CTD test cable, NMEA test cable, remote output cable, serial data cable, rack mount kit, SEASOFT software, & complete documentation. For photos of standard shipment, click here.

9plus provides real-time data when controlled with 11plus V2 Deck Unit. 11plus V2 provides power, decodes data stream, passes data to computer, & allows user control of water sampler.

Notes:
- Computer, slip ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird.
- When used without water sampler, 9plus is deployed in vertical orientation.
- Standard & optional auxiliary sensors on 9plus not shown.
- Version of 11plus in current production is referred to as 11plus V2.
- Seasave version 7.18 or later also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit).
SBE 11plus V2 Spares & Accessories
    
11plus V2 Back Panel -- many of remaining parts relate to connections to back panel
31043 Hardigg Case, AL-2221-0604, White, air tight, breather valve, SS hardware Hardigg shipping case holds SBE 11plus.
17556 Deck Unit signal input cable (from slip rings to Deck Unit), 10m (DN 31371) Pigtail connects Sea Cable on 11plus V2 to slip rings.
17557 Deck Unit signal input cable (from slip rings to Deck Unit), 20m (DN 31371)
17841 Deck Unit signal input cable (from slip rings to Deck Unit), 30m (DN 31371)
17912 Deck Unit signal input cable (from slip rings to Deck Unit), 50m (DN 31371)
50086 2-pin connector, deck unit seacable input Connects to Sea Cable on 11plus V2. Included with standard shipment; this is spare.
80915 Test cable, 11/33/36 deck unit to 9/32/PDIM, 10 m (DN 31314) Connects Sea Cable on 11plus V2 to 9plus CTD for testing. Included with standard shipment; this is spare.
801422 NMEA Test Cable, DB-9S to MS3106A, SBE 11p/33/36/45, 1.8 m (DN 32786) Connects NMEA Input on 11plus V2 to computer simulating NMEA input for testing 11plus V2 NMEA interface. Included with standard shipment; this is spare.
NMEA simulation program, NMEATest, is part of SEASOFT software, & is installed when you install SBE Data Processing.
801429 Remote Data Output Test Cable, DB-9S to MS3106A, 1.8 m (DN 32799) Connects Remote Out on 11plus V2 to computer to set up Remote Output interface. Cable is included with standard shipment; this is spare.
171887 RS-232 serial cable, DB-9F to DB-9M, 3 m (171887) Connects SBE 11 Interface (RS-232) or Modem Channel on 11plus V2 to computer COM ports. Two cables included with standard shipment; this is spare.
801367 Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704) Connects Surface PAR Input on 11plus V2 to Surface PAR sensor.
801368 Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704)
171890 RS-232 serial data uplink cable, DB-9P to DB-9S, 3 m Null modem cable connects computer to Serial Data Uplink on 11plus V2 back panel. See 171890 for pinouts.

300 baud modem for water sampler control (see note below) & either 9p-11a or 9p-11b is required to support serial data uplink. Serial data is multiplexed into 9plus telemetry stream & de-multiplexed by 11plus V2, outputting to computer through standard 9600 Baud Uplink connector. System supports use of serial data output instrument & water sampler in same cast.

If 9p-11b (19200 baud) selected, continuous transmission rate may not exceed 9600 baud (960 bytes/second). Therefore, serial data output instrument must transmit at 19200 baud in burst mode (transmissions separated by intervals with no data transmission, resulting in average rate of 960 bytes/second).

*Note: 300 baud modem in 9plus & 11plus has been standard since early 2005. For older instruments, it was optional.
17015 AC power cord (US Standard), 2 m One of these (as applicable) as included with standard shipment; this is spare.
17824 AC power cord, European plug, 2 m
30017 SBE 11plus rack mounting kit (spare) For mounting 11plus V2 in standard rack. Included with standard shipment; this is spare. See document 67059.
80673 11plus modem board  
40934C Receiver Board  
40937C Digital Board  
20033 Mallory SC628MN alarm buzzer Alarm sounds based on data from bottom contact switch &/or altimeter connected to 9plus, &/or minimum/maximum user-input pressure values.
22002 Primary power supply (Power One HTAA-16W-A)  
80811 NMEA interface board (V1 deck units only)  
80040 LED display board 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout.
20018 Cooling Fan  
80586 11plus sea cable power supply  
19006 Thumbwheel switch 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout.

 

Product configuration options listing for all products

Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts

div.gif (3436 bytes)

Last modified: 11 Apr 2011

Sea-Bird Home     Phone: (+1) 425-643-9866     Fax: (+1) 425-643-9954     E-mail: seabird@seabird.com