This page contains links to:
SBE | Description |
Brochure / Specifications |
Manual |
Reference Sheet |
Configuration options & accessories |
Other/Notes |
3S | Oceanographic Temperature Sensor | Brochure - html or pdf | -- | -- | Configuration | |
3F | CTD Temperature Sensor | Brochure - html or pdf | -- | -- | Configuration | Modular sensor used in 25. |
3plus | Premium CTD Temperature Sensor | Brochure - html or pdf | -- | -- | Configuration | Modular sensor used in 9plus. |
4 | Conductivity Sensor | Brochure - html or pdf | -- | -- |
Configuration - 4C or 4M |
SBE 4C is modular sensor used in
9plus
& 25; SBE 4M is modular sensor used optionally in 26, 26plus, & 53. See Application Note 70: Installing Anti-Foulant Device Mount Kit |
5M | Miniature Submersible Pump | Brochure - html or pdf | -- | -- | Configuration |
Modular pump used in 19plus/19plus
V2
& optionally in SBE 16plus/16plus V2 &
16plus-IM/16plus-IM
V2. See Application Note 75: Maintenance of Pumps |
5T & 5P |
Submersible Pump: 5T Titanium 5P Plastic |
Brochure - html or pdf | -- | -- |
Configuration - 5T or 5P |
Modular pump used in 9plus
& 25 & optionally in 16plus/16plus V2,
16plus-IM/16plus-IM
V2, & 19plus/19plus
V2. See Application Notes: - 40: Pump Speed Adjustment Instructions - 75: Maintenance of Pumps |
7 | Microstructure Conductivity Sensor | Brochure - html or pdf | -- | -- | Configuration | |
8 | Microstructure Temperature Sensor | Brochure - html or pdf | -- | -- | Configuration | |
9plus | CTD | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | Referred to as 911plus when used with 11plus CTD Deck Unit (real-time data acquisition) or 917plus when used with 17plus V2 SEARAM Recorder & Auto Fire Module (autonomous operation). |
11plus V2 | CTD Deck Unit |
Current manual All manuals |
-- | Configuration | See 9plus above. | |
11plus V1 | CTD Deck Unit | -- | Manual | -- | -- | Not in production since 1997; 11plus V2 is current model. |
13 | Dissolved Oxygen Sensor | Brochure - html | -- | -- | -- | Not in production since 2001; 43 is current model. |
14 | Remote Depth Readout | Brochure - html or pdf | -- | -- | Configuration | See Application Note 17: Instructions for Use. |
16plus V2 | SEACAT V2 C-T (P optional) Recorder with RS-232 Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
SEACAT V2 C-T (P optional) Recorder with RS-485 Interface | Manual (not available yet) | Reference Sheet (not available yet) | ||||
16plus | SEACAT C-T (P optional) Recorder with RS-232 Interface | -- | Manual | Reference Sheet | -- | Not in production since February 2008; 16plus V2 is current model. |
SEACAT C-T (P optional) Recorder with RS-485 Interface | Manual | Reference Sheet | -- | |||
16 | SEACAT C-T (P optional) Recorder | -- | Manual | -- | -- | Not in production since 2001; 16plus V2 is current model. |
16plus-IM V2 | SEACAT V2 C-T (P optional) Recorder with Inductive Modem Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration |
|
16plus-IM | SEACAT C-T (P optional) Recorder with Inductive Modem Interface | -- | Manual | Reference Sheet | -- | Not in production since February 2008; 16plus-IM V2 is current model. |
17plus V2 | SEARAM Recorder & Auto Fire Module | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | See SBE 9plus & NiMH Battery Charger & Battery Pack. |
18 | pH Sensor | Brochure - html or pdf | -- | -- | Configuration |
See Application Notes: - 18-1: pH Sensor Calibration. - 18-2: pH Sensor Storage, Maintenance, & Calibration. - 18-3: pH Sensor Hook-Up Instructions. - 18-4: pH Sensor Calibration Equation Error. - 76: pH Sensors & Moored Applications. |
19plus V2 | SEACAT V2 Profiler CTD | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
19plus | SEACAT Profiler CTD | -- | Manual | Reference Sheet | -- | Not in production since February 2008; 19plus V2 is current model. |
19 | SEACAT Profiler CTD | -- | Manual - English or Spanish | -- | -- | Not in production since 2001; 19plus V2 is current model. |
21 | SEACAT Thermosalinograph | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | See SEACAT/SEALOGGER RS-232 & Navigation Interface Box; PN 90488 AC-powered Interface Box comes standard with 21. |
23 | Dissolved Oxygen Sensor | Brochure - html | Manual | -- | -- | Not in production since 2001; 43 is current model. |
25 | SEALOGGER CTD | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration |
|
26plus | SEAGAUGE Wave & Tide Recorder | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration |
|
26 | SEAGAUGE Wave & Tide Recorder | -- | Manual | -- | -- | Not in production since 2004; 26plus is current model. |
27 | pH / ORP (Redox) Sensor | Brochure - html or pdf | -- | -- | Configuration |
See Application Notes: - 18-1: pH Sensor Calibration. - 18-2: pH Sensor Storage, Maintenance, & Calibration. - 19: ORP Sensor. - 76: pH Sensors & Moored Applications. |
29 | Strain-Gauge Pressure Sensor | Brochure - html or pdf | -- | -- | Configuration | Modular sensor used in 25. |
31 | Multi-Channel Counter | Brochure - html or pdf | Manual | -- | Custom applications; contact Sea-Bird. | |
32 | Carousel Water Sampler |
Carousel Brochure -
html
or
pdf
|
Current manual All manuals |
-- |
Configuration -
32 (full size), 32C (compact), or 32SC (sub-compact), Spares & Accessories, Bottles & Bottle Spares |
|
33 | Carousel Deck Unit | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | |
35 | Deep Ocean Standards Thermometer | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | |
35RT | Digital Reversing Thermometer | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | |
36/PDIM | CTD Deck Unit & Power Data Interface Module | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration | |
37-SMP-IDO | MicroCAT C-T-DO (P optional) Recorder (Serial interface, Memory, integral Pump, Integrated Dissolved Oxygen) with RS-232 Interface | Brochure - html or pdf | Current manual | Reference Sheet | Configuration | |
MicroCAT C-T-DO (P optional) Recorder (Serial interface, Memory, integral Pump, Integrated Dissolved Oxygen) with RS-485 Interface | Manual not yet available | Reference Sheet not yet available | ||||
37-SMP | MicroCAT C-T (P optional) Recorder (Serial interface, Memory, & integral Pump) with RS-232 Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
MicroCAT C-T (P optional) Recorder (Serial interface, Memory, & integral Pump) with RS-485 Interface |
Current manual All manuals |
Reference Sheet | ||||
37-SM | MicroCAT C-T (P optional) Recorder (Serial interface & Memory) with RS-232 Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
MicroCAT C-T (P optional) Recorder (Serial interface & Memory) with RS-485 Interface |
Current manual All manuals |
Reference Sheet | ||||
37-SIP-IDO | MicroCAT C-T-DO (P optional) Sensor (Serial Interface, integral Pump, Integrated Dissolved Oxygen) with RS-232 Interface | Brochure - html or pdf | Current manual | Reference Sheet | Configuration | |
MicroCAT C-T-DO (P optional) Sensor (Serial Interface, integral Pump, Integrated Dissolved Oxygen) with RS-485 Interface | Manual not yet available | Reference Sheet not yet available | ||||
37-SIP | MicroCAT C-T (P optional) Sensor (Serial Interface & integral Pump) with RS-232 Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | Firmware version > 3.0 have memory |
MicroCAT C-T (P optional) Sensor (Serial Interface & integral Pump) with RS-485 Interface |
Current manual All manuals |
Reference Sheet | Firmware version > 3.0 have memory | |||
37-SI | MicroCAT C-T (P optional) Sensor (Serial Interface) with RS-232 Interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | Firmware version > 3.0 have memory |
MicroCAT C-T (P optional) Sensor (Serial Interface) with RS-485 Interface |
Current manual All manuals |
Reference Sheet | Firmware version > 3.0 have memory | |||
37-IMP-IDO | MicroCAT C-T-DO (P optional) Recorder (Inductive Modem, integral Pump, Integrated Dissolved Oxygen) | Brochure - html or pdf | Current manual | Reference Sheet | Configuration | |
37-IMP | MicroCAT C-T (P optional) Recorder (Inductive Modem & integral Pump) | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
37-IM | MicroCAT C-T (P optional) Recorder (Inductive Modem) | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
38 | Digital Oceanographic Thermometer | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
39 | Temperature (P optional) Recorder | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
39-IM | Temperature (P optional) Recorder with Inductive Modem interface | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration |
|
41 & 41CP | CTD Module for Argo Floats | Brochure - html | -- | -- |
Configuration - contact Sea-Bird |
OEM instrument. |
43 | Dissolved Oxygen Sensor | Brochure - html or pdf | -- | -- |
Configuration - 43 or 43F |
See Application Notes: - 64: Background Information, Deployment Recommendations, & Cleaning & Storage. - 64-1: Plumbing Installation on a CTD. - 64-2: Calibration & Data Corrections using Winkler Titrations. - 64-3: Hysteresis Corrections |
44 | Underwater Inductive Modem | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration |
|
45 | MicroTSG Thermosalinograph | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | See PN 90402 - SBE 45 Power, Navigation, & Remote Temperature Interface Box (optional accessory). |
46 | LCD Display Box | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
48 | Hull Temperature Sensor | -- |
Current manual All manuals |
Reference Sheet | Configuration | |
49 | FastCAT CTD Sensor | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
50 | Digital Oceanographic Pressure Sensor | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet | Configuration | |
52-MP | Moored Profiler CTD & Optional DO Sensor | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration |
|
53 | BPR Bottom Pressure Recorder | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration |
|
54 | Tsunameter (Tsunami Pressure Sensor) | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration |
|
55 | ECO Water Sampler | Brochure - html or pdf |
Current manual All manuals |
-- | Configuration |
|
56 | Temperature Logger | Brochure - html or pdf | Current Manual | Reference Sheet | Configuration | |
GPCTD | Glider Payload CTD | Brochure - html or pdf | Current manual | -- | Configuration | OEM instrument. |
-- | Slocum Glider Payload CTD | Brochure - html or pdf | -- | -- |
Configuration - contact Sea-Bird |
OEM instrument. |
-- | SEACAT/SEALOGGER RS-232 & Navigation Interface Box (previously called NMEA Interface Box) -- PN 90488 (AC-powered) or PN 90545 (DC-powered) |
See SBE 21 brochure -
html or pdf |
Current manual All manuals |
-- |
Configuration - see SBE 21 |
Included standard with 21. |
-- | SEACAT/SEALOGGER RS-232 & Navigation Interface Box (previously called NMEA Interface Box) -- PN 90158.1 (AC-powered) or PN 90204 (DC-powered) | -- | Manual | -- | -- | Not in production; PN 90488 (AC-powered) & PN 90545 (DC-powered) are current models. |
-- | PN 90402 - SBE 45 Power, Navigation, & Remote Temperature Interface Box |
See SBE 45 brochure -
html or pdf |
Current manual All manuals |
-- |
Configuration - see SBE 45 |
|
-- | Interface Boxes | Brochure - html or pdf | -- | -- | -- | Information on a number of interface boxes, compatible with a variety of instruments. |
-- | Carousel Auto Fire Module (AFM) | Brochure - html or pdf |
Current manual All manuals |
Reference Sheet |
Configuration - see
32 (full size), 32C (compact), or 32SC (sub-compact) |
|
-- | Nickel Metal Hydride (NiMH) Battery Charger & Battery Pack | -- |
Current manual All manuals |
-- |
Configuration - see 17plus V2, 19plus V2, or 25 |
Standard with 17plus V2, optional with 19plus/19plus V2 & 25. |
-- | Surface Inductive Modem (SIM) | Brochure - html or pdf | -- | -- | Configuration | See IM instrument manual for installation & use (16plus-IM, 16plus-IM V2, 37-IM, 37-IMP, 39-IM, 44) |
-- | Inductive Cable Coupler (ICC) | Brochure - html or pdf | -- | |||
-- | Inductive Modem Module (IMM) | Brochure - html or pdf | Manual - not available yet | Configuration |
See Application Notes: - 78: Quick Start. - 79: Configuring for Logic Level Serial. - 80: Communication between Two IMMs. |
|
UIMM | Underwater Inductive Modem Module | Brochure - html or pdf | -- | -- | Configuration | |
-- | SBE Improved O.T.E. Model 110 Sample Bottle | Brochure - html or pdf | -- | -- | Configuration | |
-- | Third Party Equipment -- our Third Party Equipment page contains links to websites of manufacturers of equipment routinely supplied by Sea-Bird. Specifications & manuals are available on some of these websites. | -- | -- | -- | -- | |
WQM | Water Quality Monitor | -- | -- | -- | -- | Sold by WET Labs; jointly developed by Sea-Bird and WET Labs. Click here for more details about Sea-Bird's development and testing of the WQM |
Seasave V7 for Windows (current release of real-time data acquisition software) -- manual and 1-page reference sheet |
Seasave-Win32 for Windows (obsolete real-time data acquisition software) -- manual |
SBE Data Processing for Windows (data processing software) -- manual |
SEASOFT for Waves for Windows -- software details incorporated in SBE 26, 26plus, and 53 manuals. |
Notes:
Product Quick Guide -- pdf |
Products at a Glance -- html or pdf |
Specifications are subject to change without notice.