Third Party Product Configuration Options

Sea-Bird routinely supplies these third party instruments integrated with Sea-Bird instruments, and supported by Sea-Bird software. The Sea-Bird part numbers for the third party sensors do not include the necessary interface cables or mounting hardware for mounting on Sea-Bird instruments. Order the appropriate Interface option (part number that includes 'Int') as well as the sensor. Click the third party manufacturer in the list below or scroll through the page to find the desired product.
(Where applicable, links are provided to application notes describing integration of third party sensors with Sea-Bird instruments and to drawings for cables.)

Notes:
1. We do not publish prices on the website. Please contact us for pricing (seabird@seabird.com or 425-643-9866).
2. We do not lease third party sensors. See Equipment Leasing for companies that may be able to lease Sea-Bird equipment as well as third party sensors.

Should I order third party sensors from Sea-Bird, or deal directly with the sensors' manufacturers?

Third Party Instrument Configuration:

Links to other pages:

 

Biospherical Instruments PAR Sensors

See Application Note 11General: PAR Light Sensors,
Application Note 11QSP-L: Calculating Calibration Coefficients for Biospherical PAR Sensor with Built-In Log Amplifier,
Application Note 11QSP-PD: Calculating Calibration Coefficients for Biospherical PAR Sensor without Built-in Log Amplifier,
Application Note 11S: Using Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit, and
Application Note 47: Using Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit.

24253    Biospherical QSP-2300L Quantum Scalar (4 pi) PAR (log amp) sensor, 2000 m

24315    Biospherical QSP-2300L Quantum Scalar (4 pi) PAR (log amp) sensor, 2000 m, MCBH-4MP Wet-pluggable connector

24254    Biospherical QCP-2300L Quantum (cosine) PAR (log amp) sensor, 2000 m

24321    Biospherical QCP-2300L-HP Quantum (cosine) PAR (log amp) sensor, 10,000 m

24391    Biospherical QCP-2350L Quantum (cosine) PAR (log amp) sensor, 2000 m, MCBH-4MP Wet-pluggable connector

24255    Biospherical QSP-2200 (PD) (4 pi) PAR sensor, 2000 m

24256    Biospherical QCP-2200 (PD) (cosine) PAR sensor, 2000 m

BIOInt-1a   PAR & CTD/Carousel integration for CTD with Standard connectors, includes cabling & mounting

BIOInt-1b   PAR & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling & mounting

BIOInt-2a   PAR & CTD integration for CTD with Standard connectors, includes cabling & mounting

BIOInt-2b   PAR & CTD integration for CTD with Wet-pluggable connectors, includes cabling & mounting

24257    Biospherical QSR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

24268    Biospherical QCR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

801367   Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704)

801368   Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704)

801369   Cable, QSR/QCR-2200 SPAR to Deck Unit, 50 m (DN 32704)

Campbell Scientific (formerly D & A Instruments) Optical Backscatter Sensor (turbidity)

See Application Note 81: Entering Calibration Coefficients for D&A Instruments OBS-3+ Optical Backscatter Sensor.

24311    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-1000 & 0-4000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24312    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-250 & 0-1000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24313    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-500 & 0-2000 NTU. Measures suspended solids & turbidity by optical backscatter method.

172130   Interface cable, OBS 3+, High & Low range, AG-206 to MCIL-5MP, 1 m (DN 33080)

172131   Interface cable, OBS 3+, High & Low range, Wet-pluggable, MCIL-6FS to MCIL-5MP, 1 m (DN 33081)

172109   Interface cable, OBS 3+, Low range (1X), AG-206 to MCIL-5MP, 1 m (DN 33058)

172110   Interface cable, OBS 3+, High range (4X), AG-206 to MCIL-5MP, 1 m (DN 33059)

50187     OBS 3+ sensor mount kit (strap on Seacat/Sealogger housing)

50230     OBS 3+ sensor (strap on SBE 9plus housing)

50193     OBS 3+ sensor mount block (SBE 25 cage mount)

Ocean Test Equipment (OTE) Water Sample Bottles

See SBE Improved Sample Bottles for 5 liter through 12 liter bottle sizes.

Note: Each bottle comes with materials needed for lanyards (nylon monofilament line, brass hook, nicopress sleeves, & plastic lanyard ball). For spares, see Sample Bottles & Bottle Spares.

 

70082    OTE PVC sample bottle, 1.7 liter

70190    OTE PVC sample bottle, 1.7 liter with external spring

70083    OTE PVC sample bottle, 1.7 liter with reversing thermometer assembly

70194    OTE PVC sample bottle, 1.7 liter with RTA and external spring

70074    OTE PVC sample bottle, 2.5 liter

70191    OTE PVC sample bottle, 2.5 liter with external spring

70075    OTE PVC sample bottle, 2.5 liter with reversing thermometer assembly

70195    OTE PVC sample bottle, 2.5 liter with RTA and external spring

70086    OTE PVC sample bottle, 20 liter

70192    OTE PVC sample bottle, 20 liter with external spring

70087    OTE PVC sample bottle, 20 liter with reversing thermometer assembly

70196   OTE PVC sample bottle, 20 liter with RTA and external spring

70088    OTE PVC sample bottle, 30 liter

70193    OTE PVC sample bottle, 30 liter with external spring

70089    OTE PVC sample bottle, 30 liter with reversing thermometer assembly

70197    OTE PVC sample bottle, 30 liter with RTA and external spring

Seapoint Sensors Fluorometers & Turbidity Sensors

See Application Note 48: Entering Calibration Coefficients for the Seapoint Turbidity Meter, 
Application Note 54: Entering Calibration Coefficients for the Seapoint Fluorometer, and
Application Note 77: Entering Calibration Coefficients for the Seapoint Ultraviolet Fluorometer.

24187    Seapoint Chlorophyll Fluorometer, 6000 m

24267    Seapoint Rhodamine Fluorometer, 6000 m

24301    Seapoint Ultra Violet (CDOM) Fluorometer, 6000 m

SCFInt-2a   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2b   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2c   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2d   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting

SCFInt-2e   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2f   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2g   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2h  Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting

24179    Seapoint Turbidity Meter (STM), 6000 m

STMInt-2a   STM & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (750 FTU), includes cabling & mounting

STMInt-2b   STM & CTD integration (strap-on) for CTD with Standard connectors, 5x gain (500 FTU), includes cabling & mounting

STMInt-2c   STM & CTD integration (strap-on) for CTD with Standard connectors, 20x gain (125 FTU), includes cabling & mounting

STMInt-2d   STM & CTD integration (strap-on) for CTD with Standard connectors, 100x gain (25 FTU), includes cabling & mounting

STMInt-2e   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 1x gain (750FTU), includes cabling & mounting

STMInt-2f   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 5x gain (500 FTU), includes cabling & mounting

STMInt-2g   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 20x gain (125 FTU), includes cabling & mounting

STMInt-2h  STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 100x gain (25 FTU), includes cabling & mounting

50394    3-Cable set of Seapoint gain jumper cables, 0.2 m. Includes 17972 (100x/30x), 17973 (20x/10x), & 17974 (5x/3x)

171099    Seapoint sensors interface cable (1x gain), 1.0 m (DN 32073)

17975     Seapoint gain jumper cable, 0.2 m (1x STM, Fluor, or CDOM) (DN 31879)

17974     Seapoint gain jumper cable, 0.2 m (5x STM, or 3x Fluor or CDOM) (DN 31878)

17973     Seapoint gain jumper cable, 0.2 m (20x STM, or 10x Fluor or CDOM) (DN 31877)

17972     Seapoint gain jumper cable, 0.2 m (100x STM, or 30x Fluor or CDOM) (DN 31876)

Teledyne Benthos (formerly Benthos, formerly Datasonics) Altimeters

24204    Benthos PSA-916 Altimeter, 6000 m

916Int-1a   PSA-916D & CTD/Carousel integration for CTD with Standard connectors, includes cabling & mounting

916Int-1b   PSA-916D & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling & mounting

916Int-2a  PSA-916D & CTD integration for CTD with Standard connectors, includes cabling & mounting

916Int-2b  PSA-916D & CTD integration for CTD with Wet-pluggable connectors, includes cabling & mounting

Turner Designs Fluorometers

See Application Note 74: Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer.

24271    Turner CYCLOPS-7 Chlorophyll Fluorometer, 600 m. Order optional flow cap for pumped applications separately.

CYCLOPInt-1a   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1b   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1c   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1d   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1e   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1f   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting

24292    CYCLOPS-7 Flow Through Cap (2100-600)

24291    CYCLOPS-7 solid secondary calibration standard (Chlor/Rhodamine, 2100-900)

WET Labs Fluorometers, Transmissometers, and Light Scattering Sensors

WET Labs Fluorometers

See Application Note 41: Calculating Calibration Coefficients for the Wet Labs WETStar Fluorometer, 
Application Note 62: Calculating Calibration Coefficients for the Wet Labs ECO-AFL or ECO-FL Fluorometer, and
Application Note 72: Setting Up Wet Labs ECO-FL Fluorometer with Bio-Wiper.

24190    Wet Labs WETStar Chlorophyll fluorometer for pumped applications, 75 µg/l range, 600 m

24191    Wet Labs WETStar Chlorophyll fluorometer for pumped applications, 150 µg/l range, 600 m

24261    Wet Labs WETStar CDOM Fluorometer for pumped applications, 600 m

WSInt-2a   WETStar & CTD Integration for CTD with Standard connectors, includes cabling & mounting

WSInt-2b   WETStar & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

24245    Wet Labs ECO-FL(RT), Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 600 m, includes setup cable PN 801793

24258    Wet Labs ECO-FL(RT)D, Deep Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 6000 m, includes setup cable PN 801793

24270    Wet Labs ECO-FLS, Chlorophyll fluorometer with bio-wiper™, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 300 m, includes setup cable PN 801793

24336     Wet Labs ECO-CD(RT), CDOM fluorometer, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 600 m, includes setup cable PN 801793

24347     Wet Labs ECO-CDS, CDOM fluorometer with bio-wiper™, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 300 m, includes setup cable PN 801793

WET Labs Combined Fluorometer / Turbidity Sensors

24339     Wet Labs ECO-FLNTU(RT), Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU, 600 m

24272    Wet Labs ECO-FLNTU(RT) Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU, 600 m

24327    Wet Labs ECO-FLNTU(RT) Chlorophyll & Turbidity sensor, 50 µg/l & 100 NTU, 600 m

24366    Wet Labs ECO-FLNTU(RT) Chlorophyll & Turbidity sensor, 75 µg/l & 200 NTU, 600 m

24340     Wet Labs ECO-FLNTU(RT), Chlorophyll & Turbidity sensor, 125 µg/l & 1000 NTU, 600 m

24376    Wet Labs ECO-FLNTU(RT)D Deep Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU, 6000 m

24297    Wet Labs ECO-FLNTU(RT)D Deep Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU, 6000 m

24368    Wet Labs ECO-FLNTU(RT)D Deep Chlorophyll & Turbidity sensor, 125 µg/l & 1000 NTU, 6000 m

WET Labs Combined Fluorometer / Turbidity Sensors with Bio-Wipers

24375    Wet Labs ECO-FLNTUS Chlorophyll & Turbidity sensor with bio-wiper™, 30 µg/l & 10 NTU, 300 m

24273    Wet Labs ECO-FLNTUS Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 25 NTU, 300 m

24374    Wet Labs ECO-FLNTUS Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 100 NTU, 300 m

24350    Wet Labs ECO-FLNTUS Chlorophyll & Turbidity sensor with bio-wiper™, 75 µg/l & 200 NTU, 300 m

24380    Wet Labs ECO-FLNTUS Chlorophyll & Turbidity sensor with bio-wiper™, 125 µg/l & 1000 NTU, 300 m

ECOInt-2a   ECO & CTD Integration for CTD with Standard connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

WET Labs Transmissometers

See Application Note 7: Calculation of Calibration Coefficients for Transmissometers.

24351    Wet Labs C-Star Transmissometer, 25 cm path, cs-25-650-p (red), Wet-pluggable, 600 m

24352    Wet Labs C-Star Transmissometer, 25 cm path, cs-25-530-p (green), Wet-pluggable, 600 m

24353    Wet Labs C-Star Transmissometer, 10 cm path, cs-10-650-p (red), Wet-pluggable, 600 m

24354    Wet Labs C-Star Transmissometer, Deep, 25 cm path, cs-25-650 (red), Wet-pluggable, 6000 m

24355    Wet Labs C-Star Transmissometer, Deep, 25 cm path, cs-25-530 (green), Wet-pluggable, 6000 m

24298    Wet Labs C-Star  flow tube (CSFTLR-25), 25 cm

24299    Wet Labs C-Star  flow tube (CSFTLR-10), 10 cm

CSint-2a   C-Star & CTD Integration for CTD with Standard connectors, includes cabling & mounting

CSint-2b   C-Star & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

CSint-3a   C-Star & CTD/Carousel Integration (32C/32SC pod) for CTD with Standard connectors, includes cabling & mounting

CSint-3b   C-Star & CTD/Carousel Integration (32C/32SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting

WET Labs Turbidity, Backscattering, and PAR Sensors

See Application Note 87: Calculating Calibration Coefficients for the Wet Labs ECO-BB Scattering/Turbidity Meter 

24345    Wet Labs ECO-NTU(RT), Turbidity Meter, 30, 60, 125 NTU range available (125 NTU default unless otherwise specified), includes setup cable PN 801793, 600 m

24346    Wet Labs ECO-NTU(RT)D, Deep Turbidity Meter, 30, 60, 125 NTU range available (125 NTU default unless otherwise specified), includes setup cable PN 801793, 6000 m

24367    Wet Labs ECO-NTU(RT), Turbidity Meter, 250, 500, 1000 NTU range available (1000 NTU default unless otherwise specified), includes setup cable PN 801793, 600 m

24348    Wet Labs ECO-NTUS, Turbidity Meter with bio-wiper™, 30, 60, 125 NTU range available (125 NTU default unless otherwise specified), includes setup cable PN 801793, 300 m

24259    Wet Labs ECO-BB(RT), Single-angle Backscattering Meter (0-5 m-1), 600 m

24260    Wet Labs ECO-BB(RT)D, Deep Single-angle Backscattering Meter (0-5 m-1), 6000 m

24344    Wet Labs ECO-BBS, Single-angle Backscattering Meter with bio-wiper™ (0-5 m-1), 300 m

24349    Wet Labs ECO-PAR(S), PAR sensor (400-700 nm), cosine response, with bio-wiper™, 300 m

ECOInt-2a   ECO & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting