Descriptions and links on this page are provided as a convenient information source to our customers. Sea-Bird recommends products listed on this page, only to the extent that they are known to be of good quality, and are electronically, mechanically, and functionally compatible with Sea-Bird instruments and software (when used as suggested by Sea-Bird). Descriptions are current as of January 2013, but may be changed by the sensor manufacturer at any time.
For ordering Third Party sensors from Sea-Bird, see Third Party Product Configuration Options.
The following sensors are compared below:
| Manufacturer | Model # | Measurement Type 1 | Output Type 2 | Maximum Depth | Comments |
| WET Labs | ECO-PAR(S) |
Cosine |
Built-in log amplifier | 300 m | Bio-wiper to minimize fouling in moored applications; MCBH connector |
| Satlantic | SatPAR |
Cosine |
Optional built-in log amplifier |
600 or 7000 m |
Voltage or RS-232 output; MCBH connector |
| Biospherical | QSP-2300L |
4 pi |
Built-in log amplifier | 2000 m | LSG connector |
| QSP-2350L |
4 pi |
Built-in log amplifier | 2000 m | MCBH connector | |
| QCP-2300L |
Cosine |
Built-in log amplifier | 2000 m | LSG connector | |
| QCP-2350L | Cosine | Built-in log amplifier | 6350 m | MCBH connector | |
| QCP-2300L-HP | Cosine | Built-in log amplifier | 10000 m | XSG connector | |
| QCP-2350L-HP | Cosine | Built-in log amplifier | 10000 m | BH connector | |
| QSP-2200 (PD) | 4 pi | Requires log amplifier | 2000 m | LSG connector | |
| QCP-2200 (PD) | Cosine | Requires log amplifier | 2000 m | LSG connector | |
1 Measurement Type:
2 Output Type:
|
|||||
| Manufacturer | Model # | Measures | Pumped? |
Output Range 1 |
Maximum Depth | Comments |
| WET Labs | WETStar | Chlorophyll | √ | 75, 150 ug/l (factory-set) | 600 m | Also available as non-pumped |
| WETStar | CDOM | √ | 350 ppb | 600 m | Also available as non-pumped | |
| ECO-FL(RT) | Chlorophyll | 30, 50, 125 ug/l | 600 m | |||
| ECO-FL(RT)D | Chlorophyll | 30, 50, 125 ug/l | 6000 m | |||
| ECO-FLS | Chlorophyll | 30, 50, 125 ug/l | 300 m | Bio-Wiper 2 | ||
| ECO-FLCD(RT) | CDOM | 125, 250, 500 ppb | 600 m | |||
| ECO-FLCD(RT)D | CDOM | 125, 250, 500 ppb | 6000 m | |||
| ECO-FLCDS | CDOM | 125, 250, 500 ppb | 300 m | Bio-Wiper 2 | ||
| Seapoint | Chlorophyll |
Chlorophyll |
5, 15, 50, 150 ug/l | 6000 m | ||
| Rhodamine | Rhodamine | 5, 15, 50, 150 ug/l | 6000 m | |||
| Ultraviolet (CDOM) |
Ultraviolet (CDOM) |
50, 150, 500, 1500 ug/l | 6000 m | |||
| Turner | Cyclops-7 |
Chlorophyll |
√ (with optional flow through cap) |
50, 50, 500 ug/l | 600 m | |
|
1 WET Labs ECO ranges are
adjustable with WET Labs setup cable and software; Seapoint and Turner ranges are adjustable with jumper
cables. 2 WET Labs Bio-Wiper minimizes fouling in moored applications. |
||||||
| Manufacturer | Model # |
Measurement Type 1 |
Light Source Wavelength | Output Range 2 | Maximum Depth | Comments |
| WET Labs | ECO-NTU(RT) | Turbidity | 700 nm | 125, 1000 NTU | 600 m | |
| ECO-NTU(RT)D | Turbidity | 700 nm | 125, 1000 NTU | 6000 m | ||
| ECO-NTUS | Turbidity | 700 nm | 125, 250, 1000 NTU | 300 m | Bio-Wiper 3 | |
| ECO-BB(RT) | Single-angle (117 deg) backscatter | 470, 532, 650 nm | 0 - 5 m -1 | 600 m | ||
| ECO-BB(RT)D | Single-angle (117 deg) backscatter | 470, 532, 650 nm | 0 - 5 m -1 | 6000 m | ||
| ECO-BBS | Single-angle (117 deg) backscatter | 470, 532, 650 nm | 0 - 5 m -1 | 300 m | Bio-Wiper 3 | |
| Campbell Scientific | D&A OBS 3+ |
Backscatter |
850 nm | 250, 1000 NTU | 1500 m | |
| D&A OBS 3+ | Backscatter | 850 nm | 500, 2000 NTU | 1500 m | ||
| D&A OBS 3+ |
Backscatter |
850 nm | 1000, 4000 NTU | 1500 m | ||
| Seapoint | Turbidity Meter |
Turbidity |
880 nm | 25, 125, 500 750 FTU | 6000 m | |
1 Measurement type:
2 WET Labs ECO turbidity sensor
range is factory set, but is adjustable downward with setup cable and
WET Labs software. |
||||||
| Manufacturer | Model # | Path Length | Light Source Wavelength | Pumped? | Maximum Depth | Comments |
| WET Labs | C-Star CST-10-PR | 10 cm | 650 nm (red) |
√ (with optional flow tube) |
600 m | |
| C-Star CST-25-PR | 25 cm | 650 nm (red) |
√ (with optional flow tube) |
600 m | ||
|
C-Star Deep CST-25-DR |
25 cm | 650 nm (red) |
√ (with optional flow tube) |
6000 m | ||
| C-Star CST-10-PG | 10 cm | 532 nm (green) |
√ (with optional flow tube) |
600 m | ||
| C-Star CST-25-PG | 25 cm | 532 nm (green) |
√ (with optional flow tube) |
600 m | ||
|
C-Star Deep CST-25-DG |
25 cm | 532 nm (green) |
√ (with optional flow tube) |
6000 m | ||
| Manufacturer | Model # | Measures | Pumped? | Output Range 1 | Maximum Depth | Comments |
| WET Labs | ECO-FLNTU(RT) | Chlorophyll fluorometer & Turbidity |
30 ug/l & 10 NTU, 50 ug/l & 25 NTU, 50 ug/l & 100 NTU, 75 ug/l & 200 NTU, 250 ug/l & 1000 NTU |
600 m | ||
| ECO-FLNTU(RT)D | Chlorophyll fluorometer & Turbidity |
30 ug/l & 10 NTU, 50 ug/l & 25 NTU, 50 ug/l & 100 NTU, 250 ug/l & 1000 NTU |
6000 m | |||
| ECO-FLNTUS | Chlorophyll fluorometer & Turbidity |
30 ug/l & 10 NTU, 50 ug/l & 25 NTU, 50 ug/l & 100 NTU, 75 ug/l & 200 NTU, 250 ug/l & 1000 NTU |
300 m | Bio-wiper 2 | ||
| ECO-FLbbCD Triplet | Chlorophyll fluorometer, CDOM fluorometer, & single-angle (117 deg) backscatter |
Chlorophyll 30 ug/l, CDOM 375 ppb, Backscatter (700 nm) 0-3 m -1 |
2000 m | |||
| ECO Custom Triplet | 3 sensors; any combination of fluorescence (chlorophyll, CDOM, uranine, phycoerythrin, phycocyanin, rhodamine) and scattering (blue, green, red) | 600 m | ||||
| ECO Custom Triplet-W | 600 m | Wiper 2 | ||||
|
1 ECO output ranges are
factory set. 2 Bio-wiper or Wiper minimize fouling in moored applications. |
||||||
Sea-Bird Home Phone: (+1) 425-643-9866 E-mail: seabird@seabird.com