Sea-Bird Electronics              Products            Support            Software            Sales            Service            Search/Sitemap

Third Party Product Configuration Options

Sea-Bird routinely supplies these third party instruments integrated with Sea-Bird instruments, and supported by Sea-Bird software. The Sea-Bird part numbers for the third party sensors do not include the necessary interface cables or mounting hardware for mounting on Sea-Bird instruments. Order the appropriate Interface option (part number that includes 'Int') as well as the sensor. Click the third party manufacturer in the list below or scroll through the page to find the desired product.
(Where applicable, links are provided to application notes describing integration of third party sensors with Sea-Bird instruments and to drawings for cables.)

Notes:
1. We do not publish prices on the website. Please contact us for pricing (seabird@seabird.com or 425-643-9866).
2. We do not lease third party sensors. See Equipment Leasing for companies that may be able to lease Sea-Bird equipment as well as third party sensors.

Should I order third party sensors from Sea-Bird, or deal directly with the sensors' manufacturers?

Third Party Instrument Configuration:

Links to other pages:

 

Biospherical Instruments PAR Sensors

See Glossary for a description of differences between Scalar and Cosine PAR sensors.
Application Note 11General: PAR Light Sensors,
Application Note 11QSP-L: Calculating Calibration Coefficients for Biospherical PAR Sensor with Built-In Log Amplifier,
Application Note 11QSP-PD: Calculating Calibration Coefficients for Biospherical PAR Sensor without Built-in Log Amplifier,
Application Note 11S: Using Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit, and
Application Note 47: Using Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit.

24253    Biospherical QSP-2300L Scalar (4 pi) PAR sensor, 2000 m, LSG connector

24315    Biospherical QSP-2350L Scalar (4 pi) PAR sensor, 2000 m, Wet-pluggable MCBH connector

24254    Biospherical QCP-2300L Cosine PAR sensor, 2000 m, LSG connector

24391    Biospherical QCP-2350L Cosine PAR sensor, 6350 m, Wet-pluggable MCBH connector

24321    Biospherical QCP-2300L-HP Cosine PAR sensor, 10,000 m, XSG connector

24423    Biospherical QCP-2350L-HP Cosine PAR sensor, 10,000 m, Wet-pluggable BH-4 connector

BIOInt-1a   PAR & CTD/Carousel integration for CTD with AG-206 connectors, includes cabling & mounting

BIOInt-1b   PAR & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling & mounting

BIOInt-2a   PAR & CTD integration for CTD with XSG/AG connectors, includes cabling & mounting

BIOInt-2b   PAR & CTD integration for CTD with Wet-pluggable connectors, includes cabling & mounting

17610   Interface cable, Biospherical QSP-2300/QCP-2300 (LMG-4FS) to AG-206 connector CTD, 2 m (DN 30701)

171836   Interface cable, Biospherical QSP-2300/QCP-2300 (LMG-4FS) to Wet-pluggable connector CTD (MCIL-6FS), 2 m (DN 32852)

172215   Interface cable, Biospherical QSP-2350/QCP-2350 Wet-pluggable (MCIL-4FS) to AG-206 connector CTD, 2 m (DN 32628)

172214   Interface cable, Biospherical QSP-2350/QCP-2350 Wet-pluggable (MCIL-4FS) to Wet-pluggable connector CTD (MCIL-6FS), 2 m (DN 32654)

24257    Biospherical QSR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

24268    Biospherical QCR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

801367   Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704)

801368   Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704)

801369   Cable, QSR/QCR-2200 SPAR to Deck Unit, 50 m (DN 32704)

 

Campbell Scientific (formerly D & A Instruments) Optical Backscatter Sensor (turbidity)

See Application Note 81: Entering Calibration Coefficients for D&A Instruments OBS-3+ Optical Backscatter Sensor.

24312    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-250 & 0-1000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24313    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-500 & 0-2000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24311    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-1000 & 0-4000 NTU. Measures suspended solids & turbidity by optical backscatter method.

172130   Interface cable, OBS 3+, High & Low range, AG-206 to MCIL-5MP, 1 m (DN 33080)

172131   Interface cable, OBS 3+, High & Low range, Wet-pluggable, MCIL-6FS to MCIL-5MP, 1 m (DN 33081)

50187     OBS 3+ sensor mount kit (strap on SeaCAT/Sealogger housing)

50230     OBS 3+ sensor (strap on SBE 9plus housing)

50193     OBS 3+ sensor mount block (SBE 25 cage mount)

 

OceanTest Equipment (OTE) Water Sample Bottles

See SBE Improved Sample Bottles for 5 liter through 12 liter bottle sizes.

Note: Each bottle comes with materials needed for lanyards (nylon monofilament line, brass hook, nicopress sleeves, & plastic lanyard ball). For spares, see Sample Bottles & Bottle Spares.

 

70082    OTE PVC sample bottle, 1.7 liter

70190    OTE PVC sample bottle, 1.7 liter with external spring

70074    OTE PVC sample bottle, 2.5 liter

70191    OTE PVC sample bottle, 2.5 liter with external spring

70086    OTE PVC sample bottle, 20 liter

70192    OTE PVC sample bottle, 20 liter with external spring

70088    OTE PVC sample bottle, 30 liter

70193    OTE PVC sample bottle, 30 liter with external spring

 

Satlantic Nutrient Sensors and Accessories

SUNA V2 (Submersible Ultraviolet Nitrate Analyser): 10 mm pathlength, advanced universal nitrate processing algorithm, adaptive sampling, class based nitrate calibration, serial output, 500 m pressure rating, seawater calibration, RS-232 programming cable, shipping case, and Windows software package.

SUNA V2 Interface and Logging Options
SUNAV2-1a   Add analog and SDI-12 outputs
SUNAV2-1b   Add internal logging and USB interface

SUNA V2 Calibration Option
SUNAV2-2a   Freshwater Calibration (CREDIT) instead of seawater calibration

SUNA V2 Anti-Fouling Options
SUNAV2-4   Integrated biofouling wiper, 100 m
SUNAV2-5   SUNA V2 flow cell (requires disabling of biofouling wiper if present)
SUNAV2-6   Biofouling guard (incompatible with biofouling wiper)

SUNA V2 Accessories
TBD   Battery pack cable
TBD   Battery pack attachment mount
SUNAInt-2a   SUNA & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
SUNAInt-2b   SUNA & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting

Deep SUNA (Submersible Ultraviolet Nitrate Analyser): 10 mm pathlength, advanced universal nitrate processing algorithm, adaptive sampling, internal logging, full seawater calibration, serial output and USB communications, USB programming cable, shipping case, 2000 m pressure rating, Windows software package.

Deep SUNA Options
DSUNA-5   Deep SUNA flow cell
DSUNA-6   Deep SUNA Biofouling guard
DSUNAInt-2a   Deep SUNA & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
DSUNAInt-2b   Deep SUNA & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting

Satlantic Submersible D-CELL Battery Pack: Anodized aluminum pressure case (1000 m depth rating), with delrin pressure release valve, wet pluggable MCBH-2F bulkhead connector, and zinc anode to prevent corrosion. Includes batteries. Specify: capacity and voltage selections.

Battery Pack Capacity selections
BattPack-1a   51 Ah
BattPack-1b   102 Ah

Battery Pack Voltage Selections
BattPack-2a   13.5 VDC: For powering Sea-Bird or WET Labs equipment
BattPack-2b   15 VDC: For powering Sea-Bird or Satlantic equipment

SeaFET Satlantic Ocean pH Sensor: Corrosion proof PVC housing, internal logging with 1.6 Gb of data storage, RS-232 and USB telemetry, combination flow cell / wet cap, 19.8 Ah alkaline battery pack, 70 m maximum depth rating.

SeaFET Accessories
SeaFET-1   SeaFET copper foul guard
SeaFET-2   USB programming cable
SeaFET-3   Replacement 19
SeaFET-4   USB programming cable

SatPAR Satlantic Cosine PAR (Photosynthetically Active Radiation) Sensor: Near equal spectral response from 400 – 700 nm, 12 VDC Operation. Specify: housing (depth rating) and data output selections.

See Glossary for a description of differences between Scalar and Cosine PAR sensors.

SatPAR Housing (depth rating) Selections
SatPAR-1a   600 m plastic housing
SatPAR-1b   7000 m titanium housing

SatPAR Data Output Selections
SatPAR-2a   Logarithmic Analog PAR Sensor Output (0-5 V)
SatPAR-2b   RS-232 PAR Sensor Output (19200 bps, sample rate 0.125-4 Hz)

SatPAR Integration Options
SatPARInt-1a   SatPAR & CTD/Carousel integration for CTD with XSG/AG connectors, includes cabling and mounting
SatPARInt-1b   SatPAR & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling and mounting
SatPARInt-2a   SatPAR & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
SatPARInt-2b   SatPAR & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting

 

Seapoint Sensors Fluorometers & Turbidity Sensors

See Application Note 48: Entering Calibration Coefficients for the Seapoint Turbidity Meter, 
Application Note 54: Entering Calibration Coefficients for the Seapoint Fluorometer, and
Application Note 77: Entering Calibration Coefficients for the Seapoint Ultraviolet Fluorometer.

24187    Seapoint Chlorophyll Fluorometer, 6000 m

24267    Seapoint Rhodamine Fluorometer, 6000 m

24301    Seapoint Ultra Violet (CDOM) Fluorometer, 6000 m

SCFInt-2a   Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2b   Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2c   Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2d   Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting

SCFInt-2e   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2f   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2g   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2h  Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting

24179    Seapoint Turbidity Meter (STM), 6000 m

STMInt-2a   STM & CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (750 FTU), includes cabling & mounting

STMInt-2b   STM & CTD integration (strap-on) for CTD with AG-206 connectors, 5x gain (500 FTU), includes cabling & mounting

STMInt-2c   STM & CTD integration (strap-on) for CTD with AG-206 connectors, 20x gain (125 FTU), includes cabling & mounting

STMInt-2d   STM & CTD integration (strap-on) for CTD with AG-206 connectors, 100x gain (25 FTU), includes cabling & mounting

STMInt-2e   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 1x gain (750FTU), includes cabling & mounting

STMInt-2f   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 5x gain (500 FTU), includes cabling & mounting

STMInt-2g   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 20x gain (125 FTU), includes cabling & mounting

STMInt-2h  STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 100x gain (25 FTU), includes cabling & mounting

171099    Interface cable, Seapoint Sensors (AG-206) to AG-206 connector CTD, 1X gain, 1 m (DN 32073)

171820    Interface cable, Seapoint Sensors (AG-206) to Wet-pluggable connector CTD (MCIL-6FS), 1X gain, 1 m (DN 32838)

50394    3-Cable set of Seapoint gain jumper cables, 0.2 m. Includes 17972 (100x/30x), 17973 (20x/10x), & 17974 (5x/3x)

171099    Seapoint sensors interface cable (1x gain), 1.0 m (DN 32073)

17975     Seapoint gain jumper cable, 0.2 m (1x STM, Fluor, or CDOM) (DN 31879)

17974     Seapoint gain jumper cable, 0.2 m (5x STM, or 3x Fluor or CDOM) (DN 31878)

17973     Seapoint gain jumper cable, 0.2 m (20x STM, or 10x Fluor or CDOM) (DN 31877)

17972     Seapoint gain jumper cable, 0.2 m (100x STM, or 30x Fluor or CDOM) (DN 31876)

 

Teledyne Benthos (formerly Benthos, formerly Datasonics) Altimeters

See Application Note 95: Setting Up Teledyne Benthos Altimeter with Sea-Bird Profiling CTD.

24204    Benthos PSA-916 Altimeter, 6000 m

916Int-1a   PSA-916D & CTD/Carousel integration for CTD with AG-206 connectors, includes cabling & mounting

916Int-1b   PSA-916D & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling & mounting

916Int-2a  PSA-916D & CTD integration for CTD with AG-206 connectors, includes cabling & mounting

916Int-2b  PSA-916D & CTD integration for CTD with Wet-pluggable connectors, includes cabling & mounting

171130  Interface cable, Benthos PSA-916 (RMG-6FS) to AG-206 connector CTD, 1.8 m (DN 32075)

171740  Interface cable, Benthos PSA-916 (RMG-6FS) to Wet-pluggable connector CTD (MCIL-6FS), 1.8 m (DN 32577)

 

Turner Designs Fluorometers

See Application Note 74: Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer.

24271    Turner CYCLOPS-7 Chlorophyll Fluorometer, stainless steel, 600 m. Order optional flow cap for pumped applications separately.

CYCLOPInt-1a   CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1b   CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1c   CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1d   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1e   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1f   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting

24292    CYCLOPS-7 Flow Through Cap (2100-600)

24291    CYCLOPS-7 solid secondary calibration standard (Chlor/Rhodamine, 2100-900)

171919  Cyclops-7 gain jumper cable, 0.2 m (100x) (DN 32921)

171920  Cyclops-7 gain jumper cable, 0.2 m (10x) (DN 32922)

 

WET Labs Fluorometers, Transmissometers, and Light Scattering Sensors

WET Labs Fluorometers

See Application Note 41: Calculating Calibration Coefficients for the WET Labs WETStar Fluorometer, 
Application Note 62: Calculating Calibration Coefficients for the WET Labs ECO-AFL or ECO-FL Fluorometer, and
Application Note 72: Setting Up WET Labs ECO-FL Fluorometer with Bio-Wiper.

24414    WET Labs WETStar (WS3S), Chlorophyll fluorometer, pumped, 75 µg/l range, Wet-pluggable, 600 m (replaces 24190)

24415    WET Labs WETStar (WS1S), Chlorophyll fluorometer, pumped, 150 µg/l range, Wet-pluggable, 600 m (replaces 24191)

WSInt-2a   WETStar & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting

WSInt-2b   WETStar & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

24245    WET Labs ECO-FLrt, Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 600 m, setup cable not included

24258    WET Labs ECO-FLrtd, Deep Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 6000 m, setup cable not included

24270    WET Labs ECO-FLs, Chlorophyll fluorometer with bio-wiper™, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 300 m, setup cable not included

24336     WET Labs ECO-FLCdrt, CDOM fluorometer, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 6000 m, setup cable not included

24373     WET Labs ECO-FLCdrtd, Deep CDOM fluorometer, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 600 m, setup cable not included

24347     WET Labs ECO-FLcds, CDOM fluorometer with bio-wiper™, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 300 m, setup cable not included

801793     Setup cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)

171953     Interface cable, WET Labs ECO-series single channel, C-Star, WETStar (MCBH-6 connector) to AG-206 connector CTD, 1 m (DN 32491)

172437     Interface cable, WET Labs ECO-series single channel, C-Star, WETStar (MCBH-6 connector) to Wet-pluggable connector CTD, 1 m (DN 32853)

172416     WETLabs jumper cable, VMG-4MP to MCIL-6FS (DN 33355)

WET Labs Combined Fluorometer / Turbidity Sensors

24339     WET Labs ECO-FLNTUrt, Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU range, 600 m

24272    WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU range, 600 m

24327    WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 50 µg/l & 100 NTU range, 600 m

24366    WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 75 µg/l & 200 NTU range, 600 m

24394    WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 250 µg/l & 1000 NTU range, 600 m

24376    WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU range, 6000 m

24297    WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU range, 6000 m

24422    WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 50 µg/l & 100 NTU range, 6000 m

24395    WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 250 µg/l & 1000 NTU range, 6000 m

WET Labs Combined Fluorometer / Turbidity Sensors with Bio-Wipers

24375    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 30 µg/l & 10 NTU range, 300 m, setup cable not included

24273    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 25 NTU range, 300 m, setup cable not included

24374    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 100 NTU range, 300 m, setup cable not included

24350    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 75 µg/l & 200 NTU range, 300 m, setup cable not included

24431    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 125 µg/l & 350 NTU range, 300 m, setup cable not included

24396    WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 250 µg/l & 1000 NTU range, 300 m, setup cable not included

ECOInt-2a   ECO & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

801793     Data I/O cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)

171869   Interface Cable, WET Labs dual channel ECO-FLNTU to AG-206 connector CTD, 1 m (DN 32812)

172285   Interface Cable, WET Labs dual channel ECO-FLNTU to Wet-pluggable connector CTD, 1 m (DN 32846)

WET Labs Three channel ECO Sensors

FLBBCD    WET Labs ECO FLBBCD Triplet, Chlorophyll (30 ug/l), backscatter (700 nm 0-3 m-1), CDOM (375 ppb), 2000 m

TRIPLET    WET Labs ECO Custom Triplet. Contact Sea-Bird/WET Labs for specific combinations. Examples: BB3 (470, 532, 650); FL3 (PE, CHL, CDOM); BBFL2 (650, CHL, CDOM); BB2FL (470, 700, CHL); 600 m

TRIPLET-W    WET Labs ECO Custom Triplet with bio-wiper™, 300 m. Contact Sea-Bird/WET Labs for specific combinations. Examples: BBFL2S (CHL, CDOM, 650).

WET Labs Transmissometers

See Application Note 7: Calculation of Calibration Coefficients for Transmissometers.

24351    WET Labs C-Star Transmissometer (CST-25-PR), 25 cm path, plastic, red (650 nm), 600 m

24352    WET Labs C-Star Transmissometer (CST-25-PG), 25 cm path, plastic, green (530 nm), 600 m

24353    WET Labs C-Star Transmissometer (CST-10-PR), 10 cm path, plastic, red (650 nm), 600 m

24354    WET Labs C-Star Transmissometer Deep (CST-25-DR), 25 cm path, red (650 nm), 6000 m

24355    WET Labs C-Star Transmissometer Deep (CST-25-DG), 25 cm path, green (530 nm), 6000 m

CSint-2a   C-Star & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting

CSint-2b   C-Star & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting

CSint-3a   C-Star & CTD/Carousel Integration (32C/32SC pod) for CTD with AG-206 connectors, includes cabling & mounting

CSint-3b   C-Star & CTD/Carousel Integration (32C/32SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting

24298    WET Labs C-Star  flow tube (CSFTLR-25), 25 cm

24299    WET Labs C-Star  flow tube (CSFTLR-10), 10 cm

WET Labs Turbidity, Backscattering, and PAR Sensors

See Application Note 87: Calculating Calibration Coefficients for the WET Labs ECO-BB Scattering/Turbidity Meter 

24345    WET Labs ECO-NTUrt, Turbidity Meter, 125 NTU range, 600 m, setup cable not included

24367    WET Labs ECO-NTUrt, Turbidity Meter, 1000 NTU range, 600 m, setup cable not included

24346    WET Labs ECO-NTUrtd, Deep Turbidity Meter, 125 NTU range, 6000 m, setup cable not included

24441    WET Labs ECO-NTUrtd, Deep Turbidity Meter, 250 NTU range, 6000 m, setup cable not included

24428    WET Labs ECO-NTUrtd, Deep Turbidity Meter, 1000 NTU range, 6000 m, setup cable not included

24348    WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 125 NTU range, 300 m, setup cable not included

24420    WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 250 NTU range, 300 m, setup cable not included

24369    WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 1000 NTU range, 300 m, setup cable not included

24259    WET Labs ECO-BBrt, 650 nm Red, Single-angle Backscattering Meter (0-5 m-1), 600 m, setup cable not included

24260    WET Labs ECO-BBrtd, 650 nm Red, Deep Single-angle Backscattering Meter (0-5 m-1), 6000 m, setup cable not included

24344    WET Labs ECO-BBs, 650 nm Red, Single-angle Backscattering Meter with bio-wiper™, (0-5 m-1), 300 m, setup cable not included

24349    WET Labs ECO-PAR(S), PAR sensor (400-700 nm) with bio-wiper™, cosine response, 300 m, setup cable not included

ECOInt-2a   ECO & CTD Integration (strap-on) for CTD with AG-206 connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting

801793     Data I/O cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)

WET Labs Water Quality Monitors

WQMx Water Quality Monitor (more details): Incorporates Sea-Bird CTD & DO sensors & WET Labs optical sensors into a single instrument depth rated to 200 m. Records Conductivity (salinity), Temperature, Pressure (depth), Dissolved Oxygen, Chlorophyll Fluorescence, CDOM fluorescence, Turbidity & Backscattering. Includes 1 GB memory, RS-232 interface, AF24173 Anti-foulant Devices, data I/O cable, software, & complete documentation. Specify: pressure sensor range (depth), chlorophyll/turbidity/CDOM sensor ranges, and input port configuration selections.

WQMx Strain Gauge Pressure Sensor Selections

WQMx-1a    100 m strain gauge pressure sensor

WQMx-1b    350 meter strain gauge pressure sensor

WQMx Chlorophyll, Turbidity, CDOM Range Selections

WQMx-2a    30 µg/l, 10 NTU, 375 ppb

WQMx-2b    50 µg/l, 25 NTU, 375 ppb

WQMx-2c    50 µg/l, 100 NTU, 375 ppb

WQMx-2d    75 µg/l, 200 NTU, 375 ppb

WQMx-2e    250 µg/l, 1000 NTU, 375 ppb

WQMx Input Port Configuration Selections

WQMx-4a    One RS-232 serial input channel

WQMx-4b    Two A/D channels (0 - 5 volt input range)

WQM Water Quality Monitor (more details): Incorporates Sea-Bird CTD & DO sensors & WET Labs optical sensors into a single instrument. Records Conductivity (salinity), Temperature, Pressure (depth), Dissolved Oxygen, Chlorophyll Fluorescence, and Turbidity. Includes 1 GB memory, RS-232 interface, 200 meter depth rated, AF24173 Anti-foulant Devices, data I/O cable, software, & complete documentation. Specify: pressure sensor range (depth) & chlorophyll & turbidity range selections.

WQM Strain Gauge Pressure Sensor Selections

WQM-1a    100 m strain gauge pressure sensor

WQM-1b    350 meter strain gauge pressure sensor

WQM Chlorophyll & Turbidity Range Selections

WQM-2a    30 µg/l & 10 NTU

WQM-2b    50 µg/l & 25 NTU

WQM-2c    50 µg/l & 100 NTU

WQM-2d    75 µg/l & 200 NTU

WQM-2e    250 µg/l & 1000 NTU

[HRule Image]