Sea-Bird routinely supplies these third party instruments integrated with
Sea-Bird instruments, and supported by Sea-Bird software. The Sea-Bird part
numbers for the third party sensors do not include the necessary interface
cables or mounting hardware for mounting on Sea-Bird instruments. Order the
appropriate Interface option (part number that includes 'Int') as well as the
sensor. Click the third party manufacturer in the list below
or scroll through the page to find the desired product.
(Where applicable, links are provided to application notes
describing integration of third party sensors with Sea-Bird instruments and to
drawings for cables.)
Notes:
1. We do not publish prices on the website. Please contact us for pricing (seabird@seabird.com
or 425-643-9866).
2. We do not lease third party sensors. See
Equipment Leasing for
companies that may be able to lease Sea-Bird equipment as well as third party
sensors.
Should I order third party sensors from Sea-Bird, or deal directly with the sensors' manufacturers?
Third Party Instrument Configuration:
Links to other pages:
See
Glossary for a description of differences between Scalar and Cosine
PAR sensors. 24253 Biospherical QSP-2300L Scalar (4 pi) PAR sensor,
2000 m, LSG connector 24315 Biospherical QSP-2350L Scalar (4 pi) PAR sensor,
2000 m, Wet-pluggable MCBH connector
Application
Note 11General: PAR Light Sensors,
Application Note 11QSP-L:
Calculating Calibration Coefficients for Biospherical PAR Sensor with
Built-In Log Amplifier,
Application Note 11QSP-PD:
Calculating Calibration Coefficients for Biospherical PAR Sensor without
Built-in Log Amplifier,
Application Note 11S: Using
Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit, and
Application Note 47: Using
Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit.
24254 Biospherical QCP-2300L Cosine PAR sensor, 2000 m, LSG connector
24391 Biospherical QCP-2350L Cosine PAR sensor, 6350 m, Wet-pluggable MCBH connector
24321 Biospherical QCP-2300L-HP Cosine PAR sensor, 10,000 m, XSG connector
24423 Biospherical QCP-2350L-HP
Cosine PAR sensor,
10,000 m, Wet-pluggable BH-4 connector BIOInt-1a PAR & CTD/Carousel integration
for CTD with AG-206 connectors, includes cabling & mounting
BIOInt-1b PAR & CTD/Carousel integration for CTD with
Wet-pluggable connectors, includes cabling & mounting BIOInt-2a PAR
& CTD integration for CTD with XSG/AG connectors, includes cabling &
mounting
BIOInt-2b PAR & CTD integration for CTD
with Wet-pluggable connectors, includes cabling & mounting
17610 Interface cable, Biospherical QSP-2300/QCP-2300 (LMG-4FS) to AG-206 connector CTD, 2 m (DN 30701)
171836 Interface cable, Biospherical QSP-2300/QCP-2300 (LMG-4FS) to Wet-pluggable connector CTD (MCIL-6FS), 2 m (DN 32852)
172215 Interface cable, Biospherical QSP-2350/QCP-2350 Wet-pluggable (MCIL-4FS) to AG-206 connector CTD, 2 m (DN 32628)
172214 Interface cable, Biospherical QSP-2350/QCP-2350 Wet-pluggable (MCIL-4FS) to Wet-pluggable connector CTD (MCIL-6FS), 2 m (DN 32654)
24257 Biospherical QSR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)
24268 Biospherical QCR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)
801367 Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704)
801368 Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704)
801369 Cable, QSR/QCR-2200 SPAR to Deck Unit, 50 m (DN 32704)
See Application Note 81: Entering Calibration Coefficients for D&A Instruments OBS-3+ Optical Backscatter Sensor.
24312 D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-250 & 0-1000 NTU. Measures suspended solids & turbidity by optical backscatter method.
24313 D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-500 & 0-2000 NTU. Measures suspended solids & turbidity by optical backscatter method.
24311 D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-1000 & 0-4000 NTU. Measures suspended solids & turbidity by optical backscatter method.
172130 Interface cable, OBS 3+, High & Low range, AG-206 to MCIL-5MP, 1 m (DN 33080)
172131 Interface cable, OBS 3+, High & Low range, Wet-pluggable, MCIL-6FS to MCIL-5MP, 1 m (DN 33081)
50187 OBS 3+ sensor mount kit (strap on SeaCAT/Sealogger housing)
50230 OBS 3+ sensor (strap on SBE 9plus housing)
50193 OBS 3+ sensor mount block (SBE 25 cage mount)
See SBE Improved Sample Bottles for 5 liter through 12 liter bottle sizes.
Note: Each bottle comes with materials needed for lanyards (nylon monofilament line, brass hook, nicopress sleeves, & plastic lanyard ball). For spares, see Sample Bottles & Bottle Spares.
70082 OTE PVC sample bottle, 1.7 liter
70190 OTE PVC sample bottle, 1.7 liter with external spring
70074 OTE PVC sample bottle, 2.5 liter
70191 OTE PVC sample bottle, 2.5 liter with external spring
70086 OTE PVC sample bottle, 20 liter
70192 OTE PVC sample bottle, 20 liter with external spring
70088 OTE PVC sample bottle, 30 liter
70193 OTE PVC sample bottle, 30 liter with external spring
SUNA V2 (Submersible Ultraviolet Nitrate Analyser): 10 mm pathlength, advanced universal nitrate processing algorithm, adaptive sampling, class based nitrate calibration, serial output, 500 m pressure rating, seawater calibration, RS-232 programming cable, shipping case, and Windows software package.
SUNA V2 Interface and Logging Options
SUNAV2-1a Add analog and SDI-12 outputs
SUNAV2-1b Add internal logging and USB interfaceSUNA V2 Calibration Option
SUNAV2-2a Freshwater Calibration (CREDIT) instead of seawater calibrationSUNA V2 Anti-Fouling Options
SUNAV2-4 Integrated biofouling wiper, 100 m
SUNAV2-5 SUNA V2 flow cell (requires disabling of biofouling wiper if present)
SUNAV2-6 Biofouling guard (incompatible with biofouling wiper)SUNA V2 Accessories
TBD Battery pack cable
TBD Battery pack attachment mount
SUNAInt-2a SUNA & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
SUNAInt-2b SUNA & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting
Deep SUNA (Submersible Ultraviolet Nitrate Analyser): 10 mm pathlength, advanced universal nitrate processing algorithm, adaptive sampling, internal logging, full seawater calibration, serial output and USB communications, USB programming cable, shipping case, 2000 m pressure rating, Windows software package.
Deep SUNA Options
DSUNA-5 Deep SUNA flow cell
DSUNA-6 Deep SUNA Biofouling guard
DSUNAInt-2a Deep SUNA & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
DSUNAInt-2b Deep SUNA & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting
Satlantic Submersible D-CELL Battery Pack: Anodized aluminum pressure case (1000 m depth rating), with delrin pressure release valve, wet pluggable MCBH-2F bulkhead connector, and zinc anode to prevent corrosion. Includes batteries. Specify: capacity and voltage selections.
Battery Pack Capacity selections
BattPack-1a 51 Ah
BattPack-1b 102 AhBattery Pack Voltage Selections
BattPack-2a 13.5 VDC: For powering Sea-Bird or WET Labs equipment
BattPack-2b 15 VDC: For powering Sea-Bird or Satlantic equipment
SeaFET Satlantic Ocean pH Sensor: Corrosion proof PVC housing, internal logging with 1.6 Gb of data storage, RS-232 and USB telemetry, combination flow cell / wet cap, 19.8 Ah alkaline battery pack, 70 m maximum depth rating.
SeaFET Accessories
SeaFET-1 SeaFET copper foul guard
SeaFET-2 USB programming cable
SeaFET-3 Replacement 19
SeaFET-4 USB programming cable
SatPAR Satlantic Cosine PAR (Photosynthetically Active Radiation) Sensor: Near equal spectral response from 400 – 700 nm, 12 VDC Operation. Specify: housing (depth rating) and data output selections.
See Glossary for a description of differences between Scalar and Cosine PAR sensors.
SatPAR Housing (depth rating) Selections
SatPAR-1a 600 m plastic housing
SatPAR-1b 7000 m titanium housingSatPAR Data Output Selections
SatPAR-2a Logarithmic Analog PAR Sensor Output (0-5 V)
SatPAR-2b RS-232 PAR Sensor Output (19200 bps, sample rate 0.125-4 Hz)SatPAR Integration Options
SatPARInt-1a SatPAR & CTD/Carousel integration for CTD with XSG/AG connectors, includes cabling and mounting
SatPARInt-1b SatPAR & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling and mounting
SatPARInt-2a SatPAR & CTD integration for CTD with XSG/AG connectors, includes cabling and mounting
SatPARInt-2b SatPAR & CTD integration for CTD with Wet-pluggable connectors, includes cabling and mounting
See Application Note 48:
Entering Calibration Coefficients for the Seapoint Turbidity Meter,
Application Note 54: Entering
Calibration Coefficients for the Seapoint Fluorometer, and
Application Note 77: Entering
Calibration Coefficients for the Seapoint Ultraviolet Fluorometer.
24187 Seapoint Chlorophyll Fluorometer, 6000 m
24267 Seapoint Rhodamine Fluorometer, 6000 m
24301 Seapoint Ultra Violet (CDOM) Fluorometer, 6000 m
SCFInt-2a Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-2b Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting
SCFInt-2c Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-2d Seapoint Fluorometer & CTD integration (strap-on) for CTD with AG-206 connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting
SCFInt-2e Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (150 µg/l Chlorophyll/Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-2f Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 3x gain (50 µg/l Chlorophyll/Rhodamine, 500 µg/l CDOM), includes cabling & mounting
SCFInt-2g Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (15 µg/l Chlorophyll/Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-2h Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 30x gain (5 µg/l Chlorophyll/Rhodamine, 50 µg/l CDOM), includes cabling & mounting
24179 Seapoint Turbidity Meter (STM), 6000 m
STMInt-2a STM & CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (750 FTU), includes cabling & mounting
STMInt-2b STM & CTD integration (strap-on) for CTD with AG-206 connectors, 5x gain (500 FTU), includes cabling & mounting
STMInt-2c STM & CTD integration (strap-on) for CTD with AG-206 connectors, 20x gain (125 FTU), includes cabling & mounting
STMInt-2d STM & CTD integration (strap-on) for CTD with AG-206 connectors, 100x gain (25 FTU), includes cabling & mounting
STMInt-2e STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 1x gain (750FTU), includes cabling & mounting
STMInt-2f STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 5x gain (500 FTU), includes cabling & mounting
STMInt-2g STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 20x gain (125 FTU), includes cabling & mounting
STMInt-2h STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 100x gain (25 FTU), includes cabling & mounting
171099 Interface cable, Seapoint Sensors (AG-206) to AG-206 connector CTD, 1X gain, 1 m (DN 32073)
171820 Interface cable, Seapoint Sensors (AG-206) to Wet-pluggable connector CTD (MCIL-6FS), 1X gain, 1 m (DN 32838)
50394 3-Cable set of Seapoint gain jumper cables, 0.2 m. Includes 17972 (100x/30x), 17973 (20x/10x), & 17974 (5x/3x)
171099 Seapoint sensors interface cable (1x gain), 1.0 m (DN 32073)
17975 Seapoint gain jumper cable, 0.2 m (1x STM, Fluor, or CDOM) (DN 31879)
17974 Seapoint gain jumper cable, 0.2 m (5x STM, or 3x Fluor or CDOM) (DN 31878)
17973 Seapoint gain jumper cable, 0.2 m (20x STM, or 10x Fluor or CDOM) (DN 31877)
17972 Seapoint gain jumper cable, 0.2 m (100x STM, or 30x Fluor or CDOM) (DN 31876)
See Application Note 95: Setting Up Teledyne Benthos Altimeter with Sea-Bird Profiling CTD.
24204 Benthos PSA-916 Altimeter, 6000 m
916Int-1a PSA-916D & CTD/Carousel integration for CTD with AG-206 connectors, includes cabling & mounting
916Int-1b PSA-916D & CTD/Carousel integration for CTD with Wet-pluggable connectors, includes cabling & mounting
916Int-2a PSA-916D & CTD integration for CTD with AG-206 connectors, includes cabling & mounting
916Int-2b PSA-916D & CTD integration for CTD with Wet-pluggable connectors, includes cabling & mounting
171130 Interface cable, Benthos PSA-916 (RMG-6FS) to AG-206 connector CTD, 1.8 m (DN 32075)
171740 Interface cable,
Benthos PSA-916 (RMG-6FS) to Wet-pluggable connector CTD (MCIL-6FS), 1.8 m
(DN 32577)
See Application Note 74: Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer.
24271 Turner CYCLOPS-7 Chlorophyll Fluorometer, stainless steel, 600 m. Order optional flow cap for pumped applications separately.
CYCLOPInt-1a CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1b CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1c CYCLOPS-7/CTD integration (strap-on) for CTD with AG-206 connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1d CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (500 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1e CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (50 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1f CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 100x gain (5 µg/l Chlorophyll a), includes cabling & mounting
24292 CYCLOPS-7 Flow Through Cap (2100-600)
24291 CYCLOPS-7 solid secondary calibration standard (Chlor/Rhodamine, 2100-900)
171919 Cyclops-7 gain jumper cable, 0.2 m (100x) (DN 32921)
171920 Cyclops-7 gain jumper cable, 0.2 m (10x) (DN 32922)
WET Labs Fluorometers
See Application Note 41:
Calculating Calibration Coefficients for the WET Labs WETStar Fluorometer,
Application Note 62: Calculating
Calibration Coefficients for the WET Labs ECO-AFL or ECO-FL Fluorometer, and
Application Note 72: Setting Up WET
Labs ECO-FL Fluorometer with Bio-Wiper.
24414 WET Labs WETStar (WS3S), Chlorophyll fluorometer, pumped, 75 µg/l range, Wet-pluggable, 600 m (replaces 24190)
24415 WET Labs WETStar (WS1S), Chlorophyll fluorometer, pumped, 150 µg/l range, Wet-pluggable, 600 m (replaces 24191)
WSInt-2a WETStar & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting
WSInt-2b WETStar & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting
24245 WET Labs ECO-FLrt, Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 600 m, setup cable not included
24258 WET Labs ECO-FLrtd, Deep Chlorophyll fluorometer, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 6000 m, setup cable not included
24270 WET Labs ECO-FLs, Chlorophyll fluorometer with bio-wiper™, 30, 50, 125 µg/l range (125 µg/l default unless otherwise specified), 300 m, setup cable not included
24336 WET Labs ECO-FLCdrt, CDOM fluorometer, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 6000 m, setup cable not included
24373 WET Labs ECO-FLCdrtd, Deep CDOM fluorometer, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 600 m, setup cable not included
24347 WET Labs ECO-FLcds, CDOM fluorometer with bio-wiper™, 125, 250, 500 ppb range (500 ppb default unless otherwise specified), 300 m, setup cable not included
801793 Setup cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)
171953 Interface cable, WET Labs ECO-series single channel, C-Star, WETStar (MCBH-6 connector) to AG-206 connector CTD, 1 m (DN 32491)
172437 Interface cable, WET Labs ECO-series single channel, C-Star, WETStar (MCBH-6 connector) to Wet-pluggable connector CTD, 1 m (DN 32853)
172416 WETLabs jumper cable, VMG-4MP to MCIL-6FS (DN 33355)
WET Labs Combined Fluorometer / Turbidity Sensors
24339 WET Labs ECO-FLNTUrt, Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU range, 600 m
24272 WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU range, 600 m
24327 WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 50 µg/l & 100 NTU range, 600 m
24366 WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 75 µg/l & 200 NTU range, 600 m
24394 WET Labs ECO-FLNTUrt Chlorophyll & Turbidity sensor, 250 µg/l & 1000 NTU range, 600 m
24376 WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 30 µg/l & 10 NTU range, 6000 m
24297 WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 50 µg/l & 25 NTU range, 6000 m
24422 WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 50 µg/l & 100 NTU range, 6000 m
24395 WET Labs ECO-FLNTUrtd Deep Chlorophyll & Turbidity sensor, 250 µg/l & 1000 NTU range, 6000 m
WET Labs Combined Fluorometer / Turbidity Sensors with Bio-Wipers™
24375 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 30 µg/l & 10 NTU range, 300 m, setup cable not included
24273 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 25 NTU range, 300 m, setup cable not included
24374 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 50 µg/l & 100 NTU range, 300 m, setup cable not included
24350 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 75 µg/l & 200 NTU range, 300 m, setup cable not included
24431 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 125 µg/l & 350 NTU range, 300 m, setup cable not included
24396 WET Labs ECO-FLNTUs Chlorophyll & Turbidity sensor with bio-wiper™, 250 µg/l & 1000 NTU range, 300 m, setup cable not included
ECOInt-2a ECO & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting
ECOInt-2b ECO & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting
801793 Data I/O cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)
171869 Interface Cable, WET Labs dual channel ECO-FLNTU to AG-206 connector CTD, 1 m (DN 32812)
172285 Interface Cable, WET Labs dual channel ECO-FLNTU to Wet-pluggable connector CTD, 1 m (DN 32846)
WET Labs Three channel ECO Sensors
FLBBCD WET Labs ECO FLBBCD Triplet, Chlorophyll (30 ug/l), backscatter (700 nm 0-3 m-1), CDOM (375 ppb), 2000 mTRIPLET WET Labs ECO Custom Triplet. Contact Sea-Bird/WET Labs for specific combinations. Examples: BB3 (470, 532, 650); FL3 (PE, CHL, CDOM); BBFL2 (650, CHL, CDOM); BB2FL (470, 700, CHL); 600 m
TRIPLET-W WET Labs ECO Custom Triplet with bio-wiper™, 300 m. Contact Sea-Bird/WET Labs for specific combinations. Examples: BBFL2S (CHL, CDOM, 650).
WET Labs Transmissometers
See Application Note 7: Calculation of Calibration Coefficients for Transmissometers.
24351 WET Labs C-Star Transmissometer (CST-25-PR), 25 cm path, plastic, red (650 nm), 600 m
24352 WET Labs C-Star Transmissometer (CST-25-PG), 25 cm path, plastic, green (530 nm), 600 m
24353 WET Labs C-Star Transmissometer (CST-10-PR), 10 cm path, plastic, red (650 nm), 600 m
24354 WET Labs C-Star Transmissometer Deep (CST-25-DR), 25 cm path, red (650 nm), 6000 m
24355 WET Labs C-Star Transmissometer Deep (CST-25-DG), 25 cm path, green (530 nm), 6000 m
CSint-2a C-Star & CTD Integration for CTD with AG-206 connectors, includes cabling & mounting
CSint-2b C-Star & CTD Integration for CTD with Wet-pluggable connectors, includes cabling & mounting
CSint-3a C-Star & CTD/Carousel Integration (32C/32SC pod) for CTD with AG-206 connectors, includes cabling & mounting
CSint-3b C-Star & CTD/Carousel Integration (32C/32SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting
24298 WET Labs C-Star flow tube (CSFTLR-25), 25 cm
24299 WET Labs C-Star flow tube (CSFTLR-10), 10 cm
WET Labs Turbidity, Backscattering, and PAR Sensors
See Application Note 87: Calculating Calibration Coefficients for the WET Labs ECO-BB Scattering/Turbidity Meter
24345 WET Labs ECO-NTUrt, Turbidity Meter, 125 NTU range, 600 m, setup cable not included
24367 WET Labs ECO-NTUrt, Turbidity Meter, 1000 NTU range, 600 m, setup cable not included
24346 WET Labs ECO-NTUrtd, Deep Turbidity Meter, 125 NTU range, 6000 m, setup cable not included
24441 WET Labs ECO-NTUrtd, Deep Turbidity Meter, 250 NTU range, 6000 m, setup cable not included
24428 WET Labs ECO-NTUrtd, Deep Turbidity Meter, 1000 NTU range, 6000 m, setup cable not included
24348 WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 125 NTU range, 300 m, setup cable not included
24420 WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 250 NTU range, 300 m, setup cable not included
24369 WET Labs ECO-NTUs, Turbidity Meter with bio-wiper™, 1000 NTU range, 300 m, setup cable not included
24259 WET Labs ECO-BBrt, 650 nm Red, Single-angle Backscattering Meter (0-5 m-1), 600 m, setup cable not included
24260 WET Labs ECO-BBrtd, 650 nm Red, Deep Single-angle Backscattering Meter (0-5 m-1), 6000 m
, setup cable not included24344 WET Labs ECO-BBs, 650 nm Red, Single-angle Backscattering Meter with bio-wiper™, (0-5 m-1), 300 m, setup cable not included
24349 WET Labs ECO-PAR(S), PAR sensor (400-700 nm) with bio-wiper™, cosine response, 300 m, setup cable not included
ECOInt-2a ECO & CTD Integration (strap-on) for CTD with AG-206 connectors, includes cabling & mounting
ECOInt-2b ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting
801793 Data I/O cable for WET Labs ECO sensors, MCIL-6FS to DB-9S with red/black twisted wire leads (DN 33232)
WET Labs Water Quality Monitors
WQMx Water Quality Monitor (more details): Incorporates Sea-Bird CTD & DO sensors & WET Labs optical sensors into a single instrument depth rated to 200 m. Records Conductivity (salinity), Temperature, Pressure (depth), Dissolved Oxygen, Chlorophyll Fluorescence, CDOM fluorescence, Turbidity & Backscattering. Includes 1 GB memory, RS-232 interface, AF24173 Anti-foulant Devices, data I/O cable, software, & complete documentation. Specify: pressure sensor range (depth), chlorophyll/turbidity/CDOM sensor ranges, and input port configuration selections.
WQMx Strain Gauge Pressure Sensor Selections
WQMx-1a 100 m strain gauge pressure sensor
WQMx-1b 350 meter strain gauge pressure sensor
WQMx Chlorophyll, Turbidity, CDOM Range Selections
WQMx-2a 30 µg/l, 10 NTU, 375 ppb
WQMx-2b 50 µg/l, 25 NTU, 375 ppb
WQMx-2c 50 µg/l, 100 NTU, 375 ppb
WQMx-2d 75 µg/l, 200 NTU, 375 ppb
WQMx-2e 250 µg/l, 1000 NTU, 375 ppb
WQMx Input Port Configuration Selections
WQMx-4a One RS-232 serial input channel
WQMx-4b Two A/D channels (0 - 5 volt input range)
WQM Water Quality Monitor (more details): Incorporates Sea-Bird CTD & DO sensors & WET Labs optical sensors into a single instrument. Records Conductivity (salinity), Temperature, Pressure (depth), Dissolved Oxygen, Chlorophyll Fluorescence, and Turbidity. Includes 1 GB memory, RS-232 interface, 200 meter depth rated, AF24173 Anti-foulant Devices, data I/O cable, software, & complete documentation. Specify: pressure sensor range (depth) & chlorophyll & turbidity range selections.
WQM Strain Gauge Pressure Sensor Selections
WQM-1a 100 m strain gauge pressure sensor
WQM-1b 350 meter strain gauge pressure sensor
WQM Chlorophyll & Turbidity Range Selections
WQM-2a 30 µg/l & 10 NTU
WQM-2b 50 µg/l & 25 NTU
WQM-2c 50 µg/l & 100 NTU
WQM-2d 75 µg/l & 200 NTU
WQM-2e 250 µg/l & 1000 NTU
Sea-Bird Home Phone: (+1) 425-643-9866 E-mail: seabird@seabird.com