Brochure/specifications
Manual (RS-232 or
RS-485)
Reference Sheet (RS-232
or
RS-485)
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes | |||
37SI | MicroCAT C & T (pressure optional) Sensor with Serial Interface - Includes 7000 m titanium housing, 8 MB Flash memory, RS-232C interface, data/power interface cable 801385 (cable may be deleted for credit), AF24173 Anti-Foulant Devices, SEASOFT software, & complete documentation. Quantity orders will be packed several instruments to a box & each box will contain one manual & one software CD-ROM. Single packing, with a manual & CD-ROM in each box, will be provided on request. | There are numerous
SBE 37 MicroCAT models
(SM, SMP,
SMP-IDO, SI, SIP,
SIP-IDO,
IM,
IMP, &
IMP-IDO
-- click here for comparison of
features). 37-SI MicroCAT includes:
Note that 37-SI does not include
internal batteries. See
37-SM for comparable instrument with
internal batteries. |
|||
SBE 37-SI Pressure Sensor Range (Depth) Options | |||||
37SI-1a | 20 m strain gauge pressure sensor |
Pressure
sensor is installed in end cap, & is not field replaceable / swappable. While highest
pressure rating gives you most flexibility in using 37-SI, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to pressure
sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
|
|||
37SI-1b | 100 m strain gauge pressure sensor | ||||
37SI-1c | 350 m strain gauge pressure sensor | ||||
37SI-1h | 600 m strain gauge pressure sensor | ||||
37SI-1d | 1000 m strain gauge pressure sensor | ||||
37SI-1e | 2000 m strain gauge pressure sensor | ||||
37SI-1f | 3500 m strain gauge pressure sensor | ||||
37SI-1g | 7000 m strain gauge pressure sensor | ||||
SBE 37-SI ShallowCAT Option -- Plastic (PET-P) Housing with 250 meter depth rating | |||||
37SI-2 | 250 m plastic housing instead of standard titanium housing (CREDIT) | Substituting plastic housing for standard 7000 m titanium housing provides lower cost option for shallow deployments. | |||
SBE 37-SI Alternate Serial Interface Option | |||||
37SI-3 | RS-485 (half duplex ONLY) serial interface (replaces RS-232 interface) |
Two-wire, RS-485 interface provides communication
with individual 37-SI or with all 37-SIs attached to RS-485
interface. This allows for coordination of sampling among many
instruments. However, note that half-duplex communication is
one-direction at a time (i.e., you cannot send commands & receive
data at same time). Note that RS-232 & RS-485 versions of 37-SI have separate manuals; see manual links at top of page. |
|||
SBE 37-SI Mounting Bracket Options (Specify clamp size to match O.D. of wire jacket) | |||||
37SI-4a | Plastic brackets to provide through-bolt mounting to a flat surface | See document 67096B. | |||
37SI-4b | Wire guide & mounting clamp for 1/4 in. diameter mooring wire |
Cable fits loosely through wire guide, & is clamped only at mounting.
See document
67094F. Thread for clamping to mooring cable:
|
|||
37SI-4c | Wire guide & mounting clamp for 5/16 in. diameter mooring wire | ||||
37SI-4d | Wire guide & mounting clamp for 3/8 in. diameter mooring wire | ||||
37SI-4e | Wire guide & mounting clamp for 1/2 in. diameter mooring wire | ||||
37SI-4f | Wire guide & mounting clamp for 6 mm diameter mooring wire | ||||
37SI-4g | Wire guide & mounting clamp for 8 mm diameter mooring wire | ||||
37SI-4h | Wire guide & mounting clamp for 10 mm diameter mooring wire | ||||
37SI-4i | Wire guide & mounting clamp for 12 mm diameter mooring wire | ||||
37SI-4j | Wire guide & mounting clamp for 16 mm (5/8 in.) diameter mooring wire | ||||
SBE 37-SI Wet-Pluggable Connector Option | |||||
37SI-5 | Wet-pluggable (MCBH) I/O connector instead of Standard (XSG) connector (includes data/power cable) |
Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets. 37SI-5 includes data/power cable compatible with wet-pluggable data/power connector. |
|||
SBE 37-SI Storm Shipping Case Option -- holds up to 4 SBE 37-SIs | |||||
37SI-6 | Storm shipping case (iM2950) instead of standard wood crate -- holds up to 4 SBE 37-SIs |
Storm
shipping case with custom foam inserts holds up to 4
MicroCATs of any type (except IDO MicroCATs) -- IMP, IM, SMP, SM, SIP, SI.
Price for 37SI-6 reflects a credit for deletion of our standard wood crate. |
|||
SBE 37-SI Spares & Accessories | |||||
801542 | AF24173 Anti-Foulant Device (pair, bagged, labeled for shipping) |
Anti-foulant
devices fit into anti-foulant device cups at each end of
conductivity cell. Anti-foulant devices included with standard
shipment; these are spares. Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
|||
233540 | Anti-foulant cap without hose barb, black |
This cap, without a hose barb, is a
spare, and is intended for use during deployment. Note: Do not deploy MicroCAT with barbed anti-foulant device cap(s)! |
|||
50087.1 | Cell filler/storage device with hose barbs (Application Note 34) |
This kit includes a syringe & tubing assembly, & 2
anti-foulant device caps with hose barbs. Remove installed
anti-foulant device cap(s) & replace them with caps with hose barbs
for cleaning & storage only.
|
|||
233186 | High-head pressure port plug for muddy/biologically productive environments | This pressure port plug extends beyond surface of instrument end cap, and has 4 horizontal vent holes connecting internally to a vertical vent hole. Horizontal orientation of external holes prevents deposit of sediment inside pressure port. Each of the 4 vent holes is larger than single vent hole in standard pressure port plug, significantly reducing possibility that biological growth will cover all holes. See Application Note 84: Using Instruments with Druck Pressure Sensors in Muddy or Biologically Productive Environments. | |||
801376 | Data/Power interface cable, RMG-4FS to DB-9S & 9V battery snap, 2.4 m (DN 32604) |
801376 -- Some users prefer battery snap connector instead of
red/black twisted wire leads. Order 801376 in place of 801385 if desired. 801263 -- Some users prefer battery snap connector instead of red/black twisted wire leads. If 37SI-5 (wet-pluggable connector) specified, order 801263 in place of 801206 if desired. 801385 -- Included with standard shipment; this is spare. 801206 -- Included with standard shipment if 37SI-5 (wet-pluggable connector) specified; this is spare. 801378 -- Longer (20 m), shielded cable. |
|||
801263 | Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & 9V battery snap, 2.4 m (DN 32490) | ||||
801385 | Data/Power interface cable, RMG-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32277) | ||||
801206 | Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32366) | ||||
801378 | Data / Power interface cable, shielded, RMG-4FS to DB-9S & red/black twisted wire leads, 20 m (DN 32720) | ||||
20200 | USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. | |||
31632 | Storm shipping case (iM2950) -- holds up to 4 SBE 37-SIs |
Storm
shipping case with custom foam inserts holds up to 4
MicroCATs of any type (except IDO MicroCATs) -- IMP, IM, SMP, SM, SIP, SI.
|
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts