Part # Description Notes
16plus V2 SEACATplus Version 2 Conductivity & Temperature (pressure optional) Recorder - Includes 64 MB memory, RS-232 interface, 6 differential A/D channels (0 - 5 volt input range), 1 RS-232 data input channel, AF24173 Anti-Foulant Devices, data I/O extension cable (17762), data I/O cable (801225), SEASOFT software, & complete documentation. Specify: housing (depth) selection. SBE 16plus V2 is a CTD intended for moored applications. For photos of standard shipment, click here.

SBE 16plus V2 is available with RS-485 interface in place of RS-232 interface; see Alternate Serial Interface Option below.

See:

  • SBE 16plus-IM V2 for version with Inductive Modem interface in place of RS-232 interface.
  • SBE 19plus V2 for similar CTD intended for profiling applications as well as moored applications.
  • SBE 37-SM or 37-SMP MicroCAT for CTD (conductivity, temperature, and optional pressure) without auxiliary sensor input capability.
  • SBE 37-SMP-IDO MicroCAT for CTD (conductivity, temperature, and optional pressure) and Dissolved Oxygen (no other auxiliary sensor input capability).
SBE 16plus V2 Housing (depth) Selections -- MUST SELECT ONE
16p-1a 600 m plastic housing
16plus V2 in plastic & titanium housings
16p-1b 7000 m titanium housing
16p-1c 10,500 m titanium housing
SBE 16plus V2 Strain Gauge Pressure Sensor Options
16p-2a 20 m strain gauge pressure sensor Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 16plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
  • 2000 m sensor:
    initial accuracy = 2 m (= 0.1% * 2000 m),
    resolution = 0.04 m (= 0.002% * 2000 m)
  • 7000 m sensor:
    initial accuracy = 7 m (= 0.1% * 7000 m),
    resolution = 0.14 m (= 0.002% * 7000 m)
16p-2b 100 m strain gauge pressure sensor
16p-2c 350 m strain gauge pressure sensor
16p-2s 600 m strain gauge pressure sensor
16p-2d 1000 m strain gauge pressure sensor
16p-2e 2000 m strain gauge pressure sensor
16p-2f 3500 m strain gauge pressure sensor
16p-2g 7000 m strain gauge pressure sensor
SBE 16plus V2 Digiquartz Pressure Sensor Options (substitutes for strain gauge option)
16p-2h 45 psia (20 m) Digiquartz with temperature compensation Digiquartz pressure sensors provide better accuracy (0.02% of full scale range vs 0.1% of full scale range) & resolution (Digiquartz resolution dependent on user-programmable integration time) than strain gauge pressure sensors. See SBE 16plus V2 Strain Gauge Pressure Sensor Options above for photo of pressure sensor port; when used with Digiquartz, nylon pressure capillary fitting screws into port.

Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 16plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 psia (1400 m) & 6000 psia (4200 m) sensors --

  • 2000 psia (1400 m) sensor:
    initial accuracy = 0.28 m (= 0.02% * 1400 m)
  • 6000 psia (4200 m) sensor:
    initial accuracy = 0.84 m (= 0.02% * 4200 m)
16p-2i 100 psia (60 m) Digiquartz with temperature compensation
16p-2j 200 psia (130 m) Digiquartz with temperature compensation
16p-2k 300 psia (200 m) Digiquartz with temperature compensation
16p-2l 400 psia (270 m) Digiquartz with temperature compensation
16p-2m 1000 psia (680 m) Digiquartz with temperature compensation
16p-2n 2000 psia (1,400 m) Digiquartz with temperature compensation
16p-2o 3000 psia (2,000 m) Digiquartz with temperature compensation
16p-2p 6000 psia (4,200 m) Digiquartz with temperature compensation
16p-2q 10,000 psia (6,800 m) Digiquartz with temperature compensation
16p-2r 15,000 psia (10,500 m) Digiquartz with temperature compensation
SBE 16plus V2 Submersible Pump Options
16p-4a Add SBE 5M titanium pump for sensor flushing, Standard XSG/RMG connectors (includes data I/O & pump Y-cable 17797, & mount) SBE 5M pump is intended for providing pumped conductivity only. Pump provides better conductivity response & anti-foulant protection than non-pumped configuration. SBE 5M pump is rated to 600 m with plastic housing or 10,500 m with titanium housing.

Larger, more powerful SBE 5P or 5T is required if also planning to pump auxiliary sensors (such as dissolved oxygen, etc.). SBE 5P plastic pump is rated to 600 m; SBE 5T titanium pump is rated to 10,500 m. Operational characteristics of SBE 5P & 5T are identical.

Data I/O - Pump bulkhead connector on 16plus V2 is standard, so pump can be added in field without requiring any modifications to 16plus V2. These all include pump, pump mount, & data I/O - pump Y-cable. 16p-4c, -4d, -4g, & -4h include Y-cable compatible with wet-pluggable bulkhead connectors on 16plus V2 & on pump.

16p-4b Add SBE 5T titanium pump for sensor flushing, Standard XSG/RMG connectors (includes data I/O & pump Y-cable 17797, & mount)
16p-4c Add SBE 5M titanium pump with Wet-pluggable MCBH connectors for sensor flushing (includes data I/O & pump Y-cable 172220, & mount. Requires Option 16p-5)
16p-4d Add SBE 5T titanium pump with Wet-pluggable MCBH connectors for sensor flushing (includes data I/O & pump Y-cable 172220, & mount. Requires Option 16p-5)
16p-4e Add SBE 5M plastic pump for sensor flushing, Standard XSG/RMG connectors (includes data I/O & pump Y-cable 17797, & mount)
16p-4f Add SBE 5P plastic pump for sensor flushing, Standard XSG/RMG connectors (includes data I/O & pump Y-cable 17797, & mount)
16p-4g Add SBE 5M plastic pump with Wet-pluggable MCBH connectors for sensor flushing (includes data I/O & pump Y-cable 172220, & mount. Requires Option 16p-5)
16p-4h Add SBE 5P plastic pump with Wet-pluggable MCBH connectors for sensor flushing (includes data I/O & pump Y-cable 172220, & mount. Requires Option 16p-5)
SBE 16plus V2 Wet-Pluggable Connector Option
16p-5 Wet-pluggable (MCBH) connectors instead of Standard (XSG) connectors on SEACAT bulkhead connectors & on extender & data I/O cables Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment (exception: 6-pin connectors) & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
16p-5 option includes extender & data I/O cable compatible with wet-pluggable data I/O - pump bulkhead connector.
SBE 16plus V2 Dissolved Oxygen Sensor Options
16p-7a SBE 43 Dissolved Oxygen Sensor (Mooring Configuration), 7000 m (cable & mount included, requires option 16p-4b or -4f)

SBE 43 is available in 7000 m titanium (16p-7a or -7b) or 600 m plastic (16p-7c or -7d) housing, and its connector type (standard or wet-pluggable) must match 16plus V2 connector type.

SBE 43 is plumbed in line between conductivity sensor & pump; consequently, system requires more powerful SBE 5P plastic pump (16p-4f or -4h) or SBE 5T titanium pump (16p-4b or -4d) instead of SBE 5M pump (16p-4a, -4c, -4e, or -4g). Operational characteristics of SBE 5P & 5T are identical.

SBE 43 Mooring Configuration differs from Profiling Configuration as follows:

  • Mooring Configuration uses black Tygon tubing (PN 31450) in place of clear Tygon tubing for plumbing, to reduce bio-fouling.
    Note: Currently, plenum on all SBE 43s is black; previously, black plenum was used only for Mooring Configuration.
  • Mooring Configuration uses 1 mil membrane in place of 0.5 mil membrane, to enhance long-term stability.

16p-7_ includes SBE 43, mount, & straight cable to connect sensor to 16plus V2 bulkhead connector. If connecting 2 sensors to 1 bulkhead connector, extra charge to substitute Y-cable applies in addition to 16p-7_ price.

Additional sensors not listed here ‑- fluorometers, transmissometers, turbidity meters, PAR sensors, etc. from third party manufacturers ‑- are compatible with 16plus V2. These sensors can be purchased from Sea-Bird & integrated with 16plus V2 at our factory, or you can purchase mount kits & cables from Sea-Bird & perform integration yourself. See Third Party portion of price list.
16p-7b SBE 43 Dissolved Oxygen Sensor (Mooring Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 16p-4d or -4h & 16p-5)
16p-7c SBE 43 Dissolved Oxygen Sensor (Mooring Configuration), 600 m plastic (cable & mount included, requires option 16p-4b or -4f)
16p-7d SBE 43 Dissolved Oxygen Sensor (Mooring Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 16p-4d or -4h & 16p-5)
SBE 16plus V2 Alternate Serial Interface Option
16p-10 RS-485 (half duplex) serial interface (replaces RS-232 interface) Two-wire, RS-485 interface provides communication with individual 16plus V2 or with all 16plus V2s attached to RS-485 interface. This allows for coordination of sampling among many instruments. However, note that half-duplex communication is one-direction at a time (i.e., you cannot send commands & receive data at same time).
Note that RS-232 & RS-485 versions of 16plus V2 have separate manuals; see manual links at top of page.
SBE 16plus V2 Spares & Accessories
801542 AF24173 Anti-foulant Device (pair, bagged, labeled for shipping) Anti-foulant devices fit into anti-foulant device cups at each end of conductivity cell. Anti-foulant devices included with standard shipment; these are spares.
Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments.
80291 9-cell series alkaline battery pack (solder connected) Batteries are easily accessed by unscrewing battery end cap. 16plus V2 comes standard with 9 D cell alkaline batteries (nominal 14 Ah), but can be powered with Electrochem lithium batteries for more power intensive / longer deployments.

Notes:

  • Sea-Bird does not supply Electrochem lithium batteries; you must purchase them elsewhere (see WGT's website for purchasing information). Shipping restrictions apply for Electrochem lithium batteries & assembled battery packs.
  • Lithium battery packs cannot be used with a 16plus V2 that is integrated with SBE 5T or 5P pump, because of current limitations. They can be used with a 16plus V2 with no pump, or with an SBE 5M pump.
801483 Battery pack assembly kit for 80547 9 D 10.8v/42Ah Lithium pack with instructions, cells not included (DN 67143)
801479 Battery pack assembly kit for 80540 3 DD 10.8v/30Ah Lithium pack with instructions, cells not included (DN 67144)
50434 SBE 16plusV2/19plusV2 Spares Kit (Standard connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items. Order appropriate spares kit for connector type on 16plus V2:
  • 50434 for 16plus V2 with standard connectors -- See document 67196 for complete listing of parts.
  • 50435 for 16plus V2 with wet-pluggable connectors -- See document 67197 for complete listing of parts.
50435 SBE 16plusV2/19plusV2 Spares Kit (Wet-pluggable connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items.
801225 Data I/O Cable, Standard connector (RMG-4FS) with DB-9S, 2.4 m (DN 32421) These test cables are used for setting up system & uploading data from memory after recovery. Data I/O cable connects to one of following cables:
  • 4-pin end of pump-data I/O Y-cable (for 16plus V2 used with a pump), or
  • 4-pin end of data I/O extension cable (for 16plus V2 used without a pump)
Connector type (standard or wet-pluggable) must match 16plus V2 connector type. Applicable cable is included with 16plus V2; these are spares.
801374 Data I/O cable, Wet-pluggable (MCIL-4FS) with DB-9S, 2.4 m (DN 32715)
17762 Data I/O extension cable, AG-206 to RMG-4MP, 0.8 m (DN 31605) This cable connects 6-pin data I/O pump bulkhead connector to 801225 data I/O cable, for 16plus V2 used without a pump.
177797 Y-cable, Pump-Data I/O, Standard connectors (DN 31551) These Y-cables connect 6-pin data I/O - pump bulkhead connector to pump (2-pin leg) & to data I/O cable (4-pin leg).
172220 Y-cable, Pump-Data I/O, Wet-pluggable (DN 32896)
90087

Universal plumbing kit (includes pump air release valve, Y-fitting, & tubing) -- Application note 64-1

Application Note 64-1 details installation of plumbing for SBE 43 & pump on a CTD.
50087.1 Cell filler/storage device with hose barbs (Application Note 34) For cleaning conductivity cell after each use & storing instrument between uses. See document 67043  & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
20200 USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68.
various Plumbing For assorted sizes of Tygon tubing, see SBE 5M Configuration Details.

 