Brochure/specifications
Manual - SBE 9plus
and
11plus V2
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes |
11plus V2 | DECK UNIT for 911plus CTD - Version 2 (V2) includes IEEE-488 & RS-232 interfaces, water sampler modem channel, NMEA 0183 GPS interface, A/D input channel for Surface PAR reference sensor, ASCII serial data output port, CTD pressure signal output, audible bottom contact alarm, audio tape interface, 115/230 VAC (switchable) input power, AC power cord, 10 m CTD test cable, NMEA test cable, remote output cable, serial data cable, rack mount kit, Seasoft software, & complete documentation. |
Photos
of standard shipment. 9plus provides real-time data when controlled with 11plus V2 Deck Unit. 11plus V2 provides power, decodes data stream, passes data to computer, & allows user control of water sampler. Notes: - Computer, slip ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird. - When used without water sampler, 9plus is deployed in vertical orientation. - Standard & optional auxiliary sensors on 9plus not shown. - Version of 11plus in current production is referred to as 11plus V2. - Seasave also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit). - Optional 9600 Baud Uplink is supported by current version of standard 11plus V2 (which includes water sampler modem channel and serial data interface electronics). It also requires standard water sampler modem channel in 9plus as well as serial data uplink option in 9plus. |
SBE 11plus V2 Spares & Accessories | ||
11plus V2 Back Panel -- many of remaining parts relate to connections to back panel |
||
31043 | Hardigg Case, AL-2221-0604, White, air tight, breather valve, SS hardware | Hardigg shipping case holds SBE 11plus. |
17556 | Deck Unit signal input cable (from slip rings to Deck Unit), 10m (DN 31371) | Pigtail connects Sea Cable on 11plus V2 to slip rings. |
17557 | Deck Unit signal input cable (from slip rings to Deck Unit), 20m (DN 31371) | |
17841 | Deck Unit signal input cable (from slip rings to Deck Unit), 30m (DN 31371) | |
17912 | Deck Unit signal input cable (from slip rings to Deck Unit), 50m (DN 31371) | |
50086 | 2-pin connector, deck unit seacable input | Connects to Sea Cable on 11plus V2. Included with standard shipment; this is spare. |
80915 | Test cable, 11/33/36 deck unit to 9/32/PDIM, Standard connector 10 m (DN 31314) | Connects Sea Cable on 11plus V2 to 9plus
CTD for testing. Included with standard shipment; these are spares:
|
801587 | Test cable, 11/33/36 Deck Unit to 9/32/PDIM, Wet-pluggable connector, 10 m (DN 32695) | |
801422 | NMEA Test Cable, DB-9S to MS3106A, SBE 11p/33/36/45, 1.8 m (DN 32786) | Connects NMEA
Input on 11plus V2 to computer
simulating NMEA input for testing 11plus V2 NMEA interface. Included with standard
shipment; this is spare. NMEA simulation program, NMEATest, is part of Seasoft software, & is installed when you install SBE Data Processing. |
801429 | Remote Data Output Test Cable, DB-9S to MS3106A, 1.8 m (DN 32799) | Connects Remote Out on 11plus V2 to computer to set up Remote Output interface. Cable is included with standard shipment; this is spare. |
171887 | RS-232 serial cable, DB-9F to DB-9M, 3 m (171887) | Connects SBE 11 Interface (RS-232) or Modem Channel on 11plus V2 to computer COM ports. Two cables included with standard shipment; this is spare. |
801367 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704) | Connects Surface PAR Input on 11plus V2 to Surface PAR sensor. |
801368 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704) | |
171890 | RS-232 serial data uplink cable, DB-9P to DB-9S, 3 m |
Null
modem cable connects computer to
Serial Data
Uplink on 11plus V2 back panel. See
171890 for pinouts. 300 baud modem for water sampler control (see note below) & either 9p-11a or 9p-11b is required to support serial data uplink. Serial data is multiplexed into 9plus telemetry stream & de-multiplexed by 11plus V2, outputting to computer through standard 9600 Baud Uplink connector. System supports use of serial data output instrument & water sampler in same cast. If 9p-11b (19200 baud) selected, continuous transmission rate may not exceed 9600 baud (960 bytes/second). Therefore, serial data output instrument must transmit at 19200 baud in burst mode (transmissions separated by intervals with no data transmission, resulting in average rate of 960 bytes/second). *Note: 300 baud modem in 9plus & 11plus has been standard since early 2005. For older instruments, it was optional. |
17015 | AC power cord (US Standard), 2 m | One of these (as applicable) as included with standard shipment; this is spare. |
17824 | AC power cord, European plug, 2 m | |
30017 | SBE 11plus rack mounting kit (spare) | For mounting 11plus V2 in standard rack. Included with standard shipment; this is spare. See document 67059. |
80673 | 11plus modem board | |
40934C | Receiver Board | |
40937C | Digital Board | |
20033 | Mallory SC628MN alarm buzzer | Alarm sounds based on data from bottom contact switch &/or altimeter connected to 9plus, &/or minimum/maximum user-input pressure values. |
22002 | Primary power supply (Power One HTAA-16W-A) | |
80811 | NMEA interface board (V1 deck units only) | |
80040 | LED display board | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
20018 | Cooling Fan | |
80586 | 11plus sea cable power supply | |
19006 | Thumbwheel switch | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
Sea-Bird Home Phone: (+1) 425-643-9866 Fax: (+1) 425-643-9954 E-mail: seabird@seabird.com