Brochure/specifications
Manual
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes |
36 | CTD DECK UNIT - 115/230 VAC accessory for SBE 19/19plus/19plus V2 or SBE 25/25plus CTD. Provides surface power & two-way communication via single-conductor armored cables up to 10,000 m long. Includes A/D voltage input channel for Surface PAR sensor (QSR-2200 / QCR-2200 -- PAR sensor & cable not included), NMEA 0183 GPS interface, AC power cord, sea cable connector, RS-232 serial cable, PDIM test cable, NMEA interface test cable, Seasoft software, & complete documentation. Requires use of Power/Data Interface Module (PDIM). Order 90227 or 90473 below or see also, SBE 19plus V2 or 25plus options list. | SBE 36 CTD Deck Unit & PDIM
provide surface power & real-time data acquisition & control for SBE 19,
19plus,
19plus V2,
25,
25plus, or 49
CTD, or SBE 50 Pressure Sensor, allowing deployment with 10,000 m long single-conductor
sea cables. SBE 36 is installed on ship, while PDIM is mounted on or near
CTD.
Notes:
|
SBE 36 Options | ||
90227 | Underwater Power & Data Interface Module, with standard connectors, used w/ SBE 36/33 & CTD, 6800 m (does not include CTD interface cable or mounting hardware) |
PDIM
is required to interface SBE 36 Deck Unit with CTD. PDIM housing is anodized aluminum, & is rated to 6800 m.
PDIM order includes sea cable extension cable & pigtail cable, dummy
plugs, & jackscrew kit. To order PDIM mount kit & CTD interface
cable, see SBE 36 Accessories & Spares below. Note: PDIM can also be used with SBE 33 Carousel Deck Unit (when used without an SBE 32 Carousel Water Sampler), to provide same functionality as when used with SBE 36 Deck Unit. PDIM connector type (XSG or wet-pluggable MCBH) must match CTD connector type. Wet-pluggable connectors provide easy connectability in damp (e.g., rolling, slippery deck) or cold environments (standard connectors may not seal well in extreme cold; we recommend connecting cables in warm ship’s lab rather than on deck for these conditions). Wet-pluggable connectors are not meant for literally plugging cables in submerged underwater; both our standard connectors & wet-pluggable connectors must be mated in air. |
90473 | Underwater Power & Data Interface Module, with wet-pluggable connectors, used with SBE 36/33 & CTD, 6800 m (does not include CTD interface cable or mounting hardware) | |
SBE 36 Spares & Accessories | ||
17556 | Deck Unit signal input cable (from slip rings to Deck Unit), 10 m (DN 31371) | Pigtail connects Sea Cable on SBE 36 to slip rings. |
17557 | Deck Unit signal input cable (from slip rings to Deck Unit), 20 m (DN 31371) | |
17841 | Deck Unit signal input cable (from slip rings to Deck Unit), 30 m (DN 31371) | |
17912 | Deck Unit signal input cable (from slip rings to Deck Unit), 50 m (DN 31371) | |
80915 | Test cable, 11/33/36 deck unit to 9/32/PDIM, Standard connector, 10 m (DN 31314) | Connects Sea Cable on SBE 36 to PDIM for testing; this is spare. |
801587 |
Test cable, 11/33/36 deck unit to 9/32/PDIM, Wet-pluggable, 10 m (DN 32695)
|
|
801422 | NMEA Test Cable, DB-9S to MS3106A, SBE 11p/33/36/45, 1.8 m (DN 32786) | Connects NMEA Input on SBE 36 to computer simulating NMEA input for testing SBE 36 NMEA interface. NMEA simulation program, NMEATest, is part of Seasoft software, & is installed when you install SBE Data Processing. Cable included with standard shipment; this is spare. |
171887 | RS-232 serial cable, DB-9F to DB-9M, 3 m (171887) | Connects Serial Data on SBE 36 to computer COM port. Cable included with standard shipment; this is spare. |
801367 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704) | Connects PAR Input on SBE 36 to Surface PAR sensor. |
801368 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704) | |
17015 | AC power cord (US Standard), 2 m | One of these power cords is included with standard shipment; these are spares. |
17824 | AC power cord, European plug, 2 m | |
17088 | PDIM to SBE 19/25 cable, standard connector, 1.1 m (DN 30567) | Connects PDIM to SBE 19,
19plus,
19plus V2,
25,
25plus, or 49 CTD,
or SBE 50 Pressure
Sensor (SBE 50 with 4-pin connector):
|
171792 | PDIM to SBE 19/25 cable, Wet-pluggable connector, 1.1 m (DN 32810) | |
50219 | Mounting block set for PDIM (bolt to cage) | PDIM is either mounted to CTD main housing or to CTD cage, depending on number, size, & mounting requirements of auxiliary sensors included in system. Sea-Bird engineering determines appropriate mounting when written quote is requested. For preliminary cost estimate, assume more expensive mounting option (50219). |
50154 | Mounting hardware kit - PDIM or AFM (clamp on housing) |
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
Sea-Bird Home Phone: (+1) 425-643-9866 Fax: (+1) 425-643-9954 E-mail: seabird@seabird.com