Brochure/specifications
Manual
Reference Sheet
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes | ||||
25plus | Sealoggerplus CTD - 16 Hz sampling rate. With modular temperature (SBE 3F) & conductivity (SBE 4C) sensors & TC Duct, submersible pump (SBE 5), internal strain gauge pressure sensor, 2 GB memory, eight A/D input channels (0 - 5 volt input range), two RS-232 input channels. Includes data I/O and pump Y-cable, 20 meter data I/O cable (801380), protective cage, Seasoft software, & complete documentation. Specify: housing (depth), & pressure sensor selections. | SBE 25plus, a profiling CTD, is
powered by internal batteries & records data in memory. In addition, 25plus can be deployed:
Notes: - Optional auxiliary sensors on CTDs not shown. - (real-time systems) Computer, slip-ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird. - (real-time systems) Seasave also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit). Photos of standard shipment. For other profiling CTDs, see SBE 9plus & 19plus V2. |
||||
SBE 25plus Housing (depth rating) Selections -- MUST SELECT ONE | ||||||
25p-1a | 600 m plastic housing for CTD and SBE 5P plastic pump |
Housing material & depth rating does
not apply to sensors -- SBE
3F temperature
sensor &
4C conductivity
sensor are aluminum, regardless of 25plus housing option, &
are rated for 6800 m. SBE 5P plastic pump is rated for 600 m; SBE 5T titanium pump is rated to 10,500 m. Operational characteristics of SBE 5P & 5T are identical. |
||||
25p-1c | 6800 m aluminum housing for CTD and SBE 5T titanium pump | |||||
SBE 25plus Pressure Sensor Range (Depth) Selections -- MUST SELECT ONE | ||||||
25p-2a | 20 m strain gauge pressure sensor |
Pressure
sensor is installed in connector end cap, is not field replaceable / swappable. While highest
pressure rating gives you most flexibility in using 25plus, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
|
||||
25p-2b | 100 m strain gauge pressure sensor | |||||
25p-2c | 350 m strain gauge pressure sensor | |||||
25p-2h | 600 m strain gauge pressure sensor | |||||
25p-2d | 1000 m strain gauge pressure sensor | |||||
25p-2e | 2000 m strain gauge pressure sensor | |||||
25p-2f | 3500 m strain gauge pressure sensor | |||||
25p-2g | 7000 m strain gauge pressure sensor | |||||
SBE 25plus Wet-Pluggable Connector Option | ||||||
25p-4 | Wet-pluggable (MCBH) connectors instead of Standard (XSG) connectors on C & T sensors, pump, related cables, & data I/O cable | This option includes
wet-pluggable bulkhead connectors on 25plus main housing & standard sensors
& pump as well as associated cables. Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment (exception: 6-pin connectors) & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
|
||||
SBE 25plus Auxiliary Sensor and Integration Options | ||||||
25p-5a | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 7000 m (cable & mount included) | General Information:
Sensor-Specific Information:
|
||||
25p-5b | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 25p-4) | |||||
25p-5c | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 600 m plastic (cable & mount included) | |||||
25p-5d | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 25p-4) | |||||
25p-6a | SBE 18 pH sensor, 1200 m (cable & mount included) | |||||
25p-6b | SBE 27 pH/ORP sensor, 1200 m (cable & mount included) | |||||
25p-6c | SBE 18 pH sensor with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 25p-4) | |||||
25p-6d | SBE 27 pH/ORP sensor with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 25p-4) | |||||
YMOLD | Extra charge for Y-cable to connect 2 or more sensors to 1 auxiliary sensor input bulkhead connector on CTD | |||||
25p-7a | Underwater power/data interface module (PDIM) integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware) |
SBE
36 CTD Deck Unit & PDIM provide surface power & real-time data
acquisition & control for 25plus, allowing deployment with 10,000 m long single-conductor sea cables. SBE 36 is installed on ship,
while PDIM is mounted on or near 25plus.
See SBE 36 description for more information on interface. SBE 33 Deck Unit is typically used to provide surface power & real-time data acquisition & control for 25plus & SBE 32 (32, 32C, or 32SC) Carousel Water Sampler or SBE 55 ECO Water Sampler. However, it can be used with PDIM instead of Carousel or ECO to provide same functionality as SBE 36 & PDIM. PDIM housing is anodized aluminum, & is rated to 6800 m. PDIM connector type (standard or wet-pluggable) must match 25plus connector type. 25p-7a & -7b do not include SBE 36 or 33 Deck Unit; order separately. Can substitute SBE 33 Carousel Deck Unit for SBE 36 CTD Deck Unit. |
||||
25p-7b | Underwater power/data interface module (PDIM) with Wet-pluggable connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware – Requires option 25p-4) | |||||
SBE 25plus Hardigg Shipping Case Option | ||||||
25p-8 | Hardigg shipping case (AL4915-1105) instead of standard wood crate |
Hardigg
shipping case with custom foam inserts holds 25plus
with auxiliary sensors in standard cage (SBE 9plus shown; SBE 25plus similar).
Notes regarding features of Hardigg case supplied by Sea-Bird: 1. Case does not have wheels, because we prefer that the case is not rolled along the ground: - Rolling along the ground could cause unnecessary vibration of the CTD. - Rolling over a curb could cause unnecessary impact to the CTD. 2. Case has small holes on each metal latch, into which you could insert a small, TSA-approved lock or some zip ties. Case cannot accommodate a large padlock. |
||||
SBE 25plus Spares & Accessories | ||||||
23302C | SBE 25plus stainless steel protective cage (DN 20310) | 50308 cage comes standard with 25plus; these are spares. | ||||
50308 | SBE 25plus stainless steel protective cage (23302C) with standard sensor mounts (temp/cond/pump) (DN 41192) | |||||
23303 | CTD cage mounting clamp, SBE 25/19 in SBE 25 type cage (2 per cage) | Clamps mount CTD to cage and come standard with 25plus; these are spares. | ||||
801225 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 2.5 m (DN 32421) | Data I/O cable connects to 4-pin end of pump-data I/O Y-cable. These test cables are used for setting up system & uploading data from memory after recovery. Applicable 20 m cable is included with SBE 25plus; these are spares. | ||||
801374 | Data I/O cable, Wet-pluggable (MCIL-4FS) w/ DB-9S, 2.5 m (DN 32715) | |||||
801380 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 20 m shielded (DN 31222) | |||||
801421 | Data I/O cable, Wet-pluggable connector (MCIL-4FS) w/ DB-9S, 20 m shielded (DN 32789) | |||||
20200 | USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. | ||||
50509 | SBE 25plus Sealogger CTD Support Kit (Standard connectors); contains spare communication cables, C & T sensor cables, pump/data Y-cable, connectors, dummy plugs, maintenance supplies, & other mechanical spares. | Order appropriate spares kit for connector type on 25plus: | ||||
50508 | SBE 25plus Sealogger CTD Support Kit (Wet-pluggable connectors); contains spare communication cables, C &T sensor cables, pump/data Y-cable, connectors, dummy plugs, maintenance supplies, & other mechanical spares. | |||||
17709 | Y cable, Pump-Data I/O (DN 31551) |
Cable comes standard with SBE 25plus; this
is spare. Cable connects to J7 (data I/O - pump - external power)
connector on 25plus end cap. Note: If 25plus is mounted vertically on an SBE 32C or 32SC Carousel (i.e., without cage), a cable with longer arms is required, because pump is typically mounted onto Carousel rather than onto 25plus housing. |
||||
90087 | Universal plumbing kit (includes pump air release valve, Y-fitting, & tubing) -- Application note 64-1 | Application Note 64-1 details installation of plumbing for SBE 43 & pump on a CTD. | ||||
50087 | Cell filler/storage device | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. | ||||
various | Load-bearing Data cable | These cables are for hand-hauling 25plus & acquiring real-time data. Cables are not intended for static working loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may be difficult to handle without winch. Minimum recommended cable bend radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter). See Application Note 59: A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling for specifications; see SBE 19plus V2 Configuration Details for part numbers. | ||||
various | Plumbing spares | For air bleed valve & y-fitting, snap-on connector, & assorted sizes of Tygon tubing, see SBE 5M Configuration Details. | ||||
31634 | Hardigg shipping case (AL4915-1105) |
Hardigg
shipping case with custom foam inserts holds 25plus
with auxiliary sensors in standard cage (SBE 9plus shown; 25plus similar).
1. Case does not have wheels, because we prefer that the case is not rolled along the ground: - Rolling along the ground could cause unnecessary vibration of the CTD. - Rolling over a curb could cause unnecessary impact to the CTD. 2. Case has small holes on each metal latch, into which you could insert a small, TSA-approved lock or some zip ties. Case cannot accommodate a large padlock. |
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
Sea-Bird Home Phone: (+1) 425-643-9866 Fax: (+1) 425-643-9954 E-mail: seabird@seabird.com