Sea-Bird Electronics            Products            Support            Software            Sales            Service            Search/Sitemap

SBE 37-SIP MicroCAT C-T (Pressure optional) Sensor
Configuration Details

div.gif (3429 bytes)

Brochure/specifications       Manual (RS-232 or RS-485)     Reference Sheet (RS-232 or RS-485)

Note: We do not publish prices on the website. Please contact us [seabird@seabird.com or (+1) 425-643-9866] for pricing.

Part # Description Notes
37SIP MicroCAT C & T (pressure optional) Sensor with Serial Interface & Internal Pump - Includes 7000 m titanium housing, 8 MB Flash memory, RS-232C interface, data/power cable 801385 (cable may be deleted for credit), AF24173 Anti-Foulant Devices, Seasoft software, & complete documentation. Compare features of the numerous SBE 37 MicroCAT models (SM, SMP, SMP-IDO, SMP-ODO, SI, SIP, SIP-IDO, SIP-ODO, IM, IMP, IMP-IDO, & IMP-ODO).

37-SIP MicroCAT includes:

  • Serial Interface (RS-232 standard, RS-485 optional)
  • Memory -- (current firmware version [ > 3.0] has 8 MB FLASH memory)
    Note: firmware version < 3.0 did not have memory
  • internal, integral Pump -- Pump provides improved conductivity response & improved anti-foul protection over 37-SI.
Photos of standard shipment.

Note that 37-SIP does not include internal batteries. See 37-SMP for comparable instrument with internal batteries.

SBE 37-SIP Pressure Sensor Range (Depth) Options
37SIP-1a 20 m strain gauge pressure sensor Pressure sensor is installed in end cap (behind mount clamp), & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 37-SIP, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
  • 2000 m sensor:
    initial accuracy = 2 m (= 0.1% * 2000 m),
    resolution = 0.04 m (= 0.002% * 2000 m)
  • 7000 m sensor:
    initial accuracy = 7 m (= 0.1% * 7000 m),
    resolution = 0.14 m (= 0.002% * 7000 m)
37SIP-1b 100 m strain gauge pressure sensor
37SIP-1c 350 m strain gauge pressure sensor
37SIP-1h 600 m strain gauge pressure sensor
37SIP-1d 1000 m strain gauge pressure sensor
37SIP-1e 2000 m strain gauge pressure sensor
37SIP-1f 3500 m strain gauge pressure sensor
37SIP-1g 7000 m strain gauge pressure sensor
SBE 37-SIP ShallowCAT Option -- Plastic (PET-P) Housing with 350 meter depth rating
37SIP-2 350 m plastic housing instead of standard titanium housing (CREDIT) Substituting plastic housing for standard 7000 m titanium housing provides lower cost option for shallow deployments.
SBE 37-SIP Alternate Serial Interface Option
37SIP-3 RS-485 (half duplex ONLY) serial interface (replaces RS-232 interface) Two-wire, RS-485 interface provides communication with individual 37-SIP or with all 37-SIPs attached to RS-485 interface. This allows for coordination of sampling among many instruments. However, note that half-duplex communication is one-direction at a time (i.e., you cannot send commands & receive data at same time).
Note that RS-232 & RS-485 versions of 37-SIP have separate manuals; see manual links at top of page.
SBE 37-SIP Mounting Bracket Options (Specify clamp size to match O.D. of wire jacket)
37SIP-4a Plastic brackets to provide through-bolt mounting to a flat surface See document 67218.
37SIP-4b Wire guide & mounting clamp for 1/4 in. diameter mooring wire Cable fits loosely through wire guide, & is clamped only at mounting clamp. See document 67219.

Thread for clamping to mooring cable:

  • 37SIP-1b (1/4 in. diameter): 1/4-28 UNF
  • 37SIP-1c (5/16 in. diameter): 5/16-24 UNF
  • 37SIP-1d (3/8 in. diameter): 3/8-24 UNF
  • 37SIP-1e (1/2 in. diameter): 9/16-12 UNC
  • 37SIP-1f (6 mm diameter): 1/4-20 UNF
  • 37SIP-1g (8 mm diameter): 5/16-24 UNF
  • 37SIP-1h (10 mm diameter): 7/16 -14 UNF
  • 37SIP-1i (12 mm diameter): 1/2-13 UNF
  • 37SIP-1j (16 mm, 5/8 in. diameter): 5/8-18 UNF

 

37SIP-4c Wire guide & mounting clamp for 5/16 in. diameter mooring wire
37SIP-4d Wire guide & mounting clamp for 3/8 in. diameter mooring wire
37SIP-4e Wire guide & mounting clamp for 1/2 in. diameter mooring wire
37SIP-4f Wire guide & mounting clamp for 6 mm diameter mooring wire
37SIP-4g Wire guide & mounting clamp for 8 mm diameter mooring wire
37SIP-4h Wire guide & mounting clamp for 10 mm diameter mooring wire
37SIP-4i Wire guide & mounting clamp for 12 mm diameter mooring wire
37SIP-4j Wire guide & mounting clamp for 16 mm (5/8 in.) diameter mooring wire
SBE 37-SIP Wet-Pluggable Connector Option
37SIP-5 Wet-pluggable (MCBH) I/O connector instead of Standard (XSG) connector (includes data/power cable 801206)

Standard Connector (Impulse XSG)

Wet-pluggable Connector (MCBH)

Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.

37SIP-5 includes a data/power cable compatible with wet-pluggable data/power connector.
SBE 37-SIP Storm Shipping Case Option -- holds up to 4 SBE 37-SIPs
37SIP-6 Storm shipping case (iM2950) instead of standard wood crate -- holds up to 4 SBE 37-SIPs Storm shipping case with custom foam inserts holds up to 4 MicroCATs that do not include dissolved oxygen -- IMP, IM, SMP, SM, SIP, SI.
  • Injection molded case with HPX resin plastic body, recessed wheels, automatic pressure equalization valve, hinged push-button latches, fold-down padded handle, & O-ring seal. Meets airline luggage regulations.
  • Inner dimensions:
    29 x 18 x 10.5 inches (74 x 46 x 27 cm).
  • Outer dimensions:
    31.3 x 20.4 x 12.2 inches (80 x 52 x 31 cm).

Price for 37SIP-6 reflects a credit for deletion of our standard wood crate.

SBE 37-SIP Spares & Accessories
801542 AF24173 Anti-Foulant Device pair (spare, bagged, labeled for shipping) Anti-foulant devices fit into anti-foulant device cups at conductivity cell intake and plumbing exhaust, under the conductivity cell guard. Anti-foulant devices included with standard shipment; these are spares.
Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments.
233540 Anti-foulant cap without hose barb, black (for use with SBE 37 [SM, SMP, IM, IMP, SI, SIP] with firmware version < 4.0) Anti-foulant cap holds AF24173 Anti-Foulant Device in place.

NOTE: Anti-Foulant Devices are held in place by conductivity cell guard in newer 37-SIPs (firmware version > 4.0).
801376 Data/Power interface cable, RMG-4FS to DB-9S & 9V battery snap, 2.4 m (DN 32604) 801376 -- Some users prefer battery snap connector instead of red/black twisted wire leads. Order 801376 in place of 801385 if desired.

801263 -- Some users prefer battery snap connector instead of red/black twisted wire leads. If 37SIP-5 (wet-pluggable connector) specified, order 801263 in place of 801206 if desired.

801385 -- Included with standard shipment; this is spare.

801206 -- Included with standard shipment if 37SIP-5 (wet-pluggable connector) specified; this is spare.

801378 -- Longer (20 m), shielded cable.

801263 Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & 9V battery snap, 2.4 m (DN 32490)
801385 Data/Power interface cable, RMG-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32277)
801206 Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32366)
801378 Data / Power interface cable, shielded, RMG-4FS to DB-9S & red/black twisted wire leads, 20 m (DN 32720)
20200 USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68.
233186 High-head pressure port plug for muddy/biologically productive environments (Application Note 84), for use with SBE 37 [SM, SMP, IM, IMP, SI, SIP] with firmware version < 4.0 This pressure port plug extends beyond surface of instrument end cap, and has 4 horizontal vent holes connecting internally to a vertical vent hole. If you are deploying 37-SMP in an orientation close to horizontal, with pressure port up, horizontal orientation of vent holes prevents deposit of sediment inside pressure port. Each of the 4 vent holes is larger than single vent hole in standard pressure port plug, significantly reducing possibility that biological growth will cover all holes. See Application Note 84: Using Instruments with Druck Pressure Sensors in Muddy or Biologically Productive Environments.

NOTE: High-head pressure port plug is not compatible with newer 37-SIPs (firmware version > 4.0), because pressure port plug is behind mount clamp.

31632 Storm shipping case (iM2950) -- holds up to 4 SBE 37-SIPs Storm shipping case with custom foam inserts holds up to 4 MicroCATs that do not include dissolved oxygen -- IMP, IM, SMP, SM, SIP, SI.
  • Injection molded case with HPX resin plastic body, recessed wheels, automatic pressure equalization valve, hinged push-button latches, fold-down padded handle, & O-ring seal. Meets airline luggage regulations.
  • Inner dimensions:
    29 x 18 x 10.5 inches (74 x 46 x 27 cm).
  • Outer dimensions:
    31.3 x 20.4 x 12.2 inches (80 x 52 x 31 cm).

 

Product configuration options listing for all products

Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts

div.gif (3436 bytes)

Sea-Bird Home     Phone: (+1) 425-643-9866     Fax: (+1) 425-643-9954     E-mail: seabird@seabird.com