Brochure/specifications
Manual
Reference Sheet
Note: We do not publish prices on the website. Please contact us [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
Part # | Description | Notes | ||||
25 | SEALOGGER CTD - With modular temperature & conductivity sensors (SBE 3F & SBE 4C) & TC Duct, submersible pump, modular strain gauge pressure sensor (SBE 29), 8 Mbyte memory, protective cage, & seven 12-bit auxiliary A/D input channels (four 0 - 5 volt single-ended; two 0-5 volt differential; one current-input log amplifier for PAR sensor). Includes SEASOFT software, complete documentation, & 20 m data I/O cable (801380). Specify: housing (depth), & pressure sensor selections. | SBE 25, a profiling CTD, is
powered by internal batteries & records data in memory. In addition, SBE 25 can be deployed:
- Optional auxiliary sensors on CTDs not shown. - (real-time systems) Computer, slip-ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird. - (real-time systems) Seasave version 7.18 or later also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit). For photos of standard shipment, click here. For other profiling CTDs, see SBE 9plus & 19plus V2. |
||||
SBE 25 Housing (depth rating) Selections -- MUST SELECT ONE | ||||||
25-1a | 600 m plastic housing for CTD and SBE 5P plastic pump |
Housing material & depth rating does
not apply to sensors -- SBE
3F temperature sensor,
4C conductivity sensor, &
29
pressure sensor are aluminum, regardless of SBE 25 housing option, &
are rated for 6800 m. SBE 5P plastic pump is rated for 600 m; SBE 5T titanium pump is rated to 10,500 m. Operational characteristics of SBE 5P & 5T are identical. |
||||
25-1c | 6800 m aluminum housing for CTD and SBE 5T titanium pump | |||||
SBE 25 Pressure Sensor Range (Depth) Selections -- MUST SELECT ONE | ||||||
25-2a | 20 m strain gauge pressure sensor |
SBE
29
modular pressure sensor is integrated with SBE 25, & is field replaceable / swappable. While highest
pressure rating gives you most flexibility in using SBE 25, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
|
||||
25-2b | 100 m strain gauge pressure sensor | |||||
25-2c | 350 m strain gauge pressure sensor | |||||
25-2h | 600 m strain gauge pressure sensor | |||||
25-2d | 1000 m strain gauge pressure sensor | |||||
25-2e | 2000 m strain gauge pressure sensor | |||||
25-2f | 3500 m strain gauge pressure sensor | |||||
25-2g | 7000 m strain gauge pressure sensor | |||||
SBE 25 Wet-Pluggable Connector Option | ||||||
25-4 | Wet-pluggable (MCBH) connectors instead of Standard (XSG) connectors on C, T, P sensors, pump, related cables, & data I/O cable | This option includes
wet-pluggable bulkhead connectors on SBE 25 main housing & standard sensors
& pump as well as associated cables. Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment (exception: 6-pin connectors) & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
|
||||
SBE 25 Auxiliary Sensor and Integration Options | ||||||
25-5a | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 7000 m (cable & mount included) | General Information:
Sensor-Specific Information:
|
||||
25-5b | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 25-4) | |||||
25-5c | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 600 m plastic (cable & mount included) | |||||
25-5d | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 25-4) | |||||
25-6a | SBE 18 pH sensor, 1200 m (cable & mount included) | |||||
25-6b | SBE 27 pH/ORP sensor, 1200 m (cable & mount included) | |||||
25-6c | SBE 18 pH sensor with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 25-4) | |||||
25-6d | SBE 27 pH/ORP sensor with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 25-4) | |||||
YMOLD | Extra charge for Y-cable to connect 2 or more sensors to 1 auxiliary sensor input bulkhead connector on CTD | |||||
25-7a | Underwater power/data interface module (PDIM) integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware) |
SBE
36 CTD Deck Unit & PDIM provide surface power & real-time data
acquisition & control for SBE 25, allowing deployment with 10,000 m long single-conductor sea cables. SBE 36 is installed on ship,
while PDIM is mounted on or near SBE 25.
See SBE 36 description for more information on interface. SBE 33 Deck Unit is typically used to provide surface power & real-time data acquisition & control for SBE 25 & SBE 32 (32, 32C, or 32SC) Carousel Water Sampler or SBE 55 ECO Water Sampler. However, it can be used with PDIM instead of Carousel or ECO to provide same functionality as SBE 36 & PDIM. PDIM housing is anodized aluminum, & is rated to 6800 m. PDIM connector type (standard or wet-pluggable) must match SBE 25 connector type. 25-7a & -7b do not include SBE 36 or 33 Deck Unit; order separately. Can substitute SBE 33 Carousel Deck Unit for SBE 36 CTD Deck Unit. For SBE 33, both NMEA & PAR interfaces are optional. |
||||
25-7b | Underwater power/data interface module (PDIM) with Wet-pluggable connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware – Requires option 25-4) | |||||
SBE 25 Hardigg Shipping Case Option | ||||||
25-8 | Hardigg shipping case (AL4915-1105) instead of standard wood crate |
Hardigg
shipping case with custom foam inserts holds SBE 25
with auxiliary sensors in standard cage (SBE 9plus shown; SBE 25 similar).
Notes regarding features of Hardigg case supplied by Sea-Bird: 1. Case does not have wheels, because we prefer that the case is not rolled along the ground: - Rolling along the ground could cause unnecessary vibration of the CTD. - Rolling over a curb could cause unnecessary impact to the CTD. 2. Case has small holes on each metal latch, into which you could insert a small, TSA-approved lock or some zip ties. Case cannot accommodate a large padlock. |
||||
SBE 25 Spares & Accessories | ||||||
23302C | SBE 25 stainless steel protective cage (DN 20310) | 50308 cage comes standard with SBE 25; these are spares. | ||||
50308 | SBE 25 stainless steel protective cage (23302C) with standard sensor mounts (temp/cond/press/pump) (DN 41192) | |||||
801511 | 9 NiMH cells in rechargeable drop-in pack (10.8V/8 Ah) |
|
||||
90504 | NiMH battery charger for 6, 9, or 12 cells / 8 Ah D-cell packs. Provides full recharge in 2 hours, includes AC power cord & battery charging cable | |||||
801225 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 2.5 m (DN 32421) | Data I/O cable connects to 4-pin end of pump-data I/O Y-cable. These test cables are used for setting up system & uploading data from memory after recovery. Applicable 20 m cable is included with SBE 25; these are spares. | ||||
801374 | Data I/O cable, Wet-pluggable (MCIL-4FS) w/ DB-9S, 2.5 m (DN 32715) | |||||
801380 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 20 m shielded (DN 31222) | |||||
801421 | Data I/O cable, Wet-pluggable connector (MCIL-4FS) w/ DB-9S, 20 m shielded (DN 32789) | |||||
20200 | USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. | ||||
50332 | SEALOGGER CTD Support Kit (updated); contains spare communication cables, C,T,P sensor cables, pump/data Y-cable, connectors, dummy plugs, maintenance supplies, & other mechanical spares. | Order appropriate spares kit for connector type on SBE 25: | ||||
50331 | SEALOGGER CTD Support Kit with Wet-pluggable connectors - contains spare communication cables, C,T,P sensor cables, pump/data Y-cable, connectors, dummy plugs, maintenance supplies, & other mechanical spares. | |||||
801641 | 9 Ni-Cad cells in drop-in rechargeable pack (10.8V/4.4 Ah) |
SBE
25
comes standard with alkaline batteries, but can be powered with
rechargeable Ni-Cad batteries instead. Batteries are easily accessed
by unscrewing main housing battery end cap. Note: As of January 2011, Sea-Bird does not manufacture the 90226 Ni-Cad battery charger, because parts are no longer available. We are still able to provide the battery pack, for customers who already have a charger. |
||||
17709 | Y cable, Pump-Data I/O (DN 31551) |
Cable comes standard with SBE 25; this
is spare. Cable connects to J1 (data I/O - pump - external power)
connector on SBE 25 end cap. Note: If SBE 25 is mounted vertically on an SBE 32C or 32SC Carousel (i.e., without cage), a cable with longer arms is required, because pump is typically mounted onto Carousel rather than onto SBE 25 housing. |
||||
90087 | Universal plumbing kit (includes pump air release valve, Y-fitting, & tubing) -- Application note 64-1 | Application Note 64-1 details installation of plumbing for SBE 43 & pump on a CTD. | ||||
50087 | Cell filler/storage device | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. | ||||
various | Load-bearing Data cable | These cables are for hand-hauling SBE 25 & acquiring real-time data. Cables are not intended for static working loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may be difficult to handle without winch. Minimum recommended cable bend radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter). See Application Note 59: A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling for specifications; see SBE 19plus V2 Configuration Details for part numbers. | ||||
various | Plumbing spares | For air bleed valve & y-fitting, snap-on connector, & assorted sizes of Tygon tubing, see SBE 5M Configuration Details. | ||||
31634 | Hardigg shipping case (AL4915-1105) |
Hardigg
shipping case with custom foam inserts holds SBE 25
with auxiliary sensors in standard cage (SBE 9plus shown; SBE 25 similar).
1. Case does not have wheels, because we prefer that the case is not rolled along the ground: - Rolling along the ground could cause unnecessary vibration of the CTD. - Rolling over a curb could cause unnecessary impact to the CTD. 2. Case has small holes on each metal latch, into which you could insert a small, TSA-approved lock or some zip ties. Case cannot accommodate a large padlock. |
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
Last modified: 01 Feb 2011